Registros recuperados : 2 | |
1. |  | HELAYEL, M. A.; CUNHA, N. C. da; MORON, S. E.; SILVA, P. C. A. R. da; UNHA, I. M. da; CHENARD, M. G.; CARVALHO, V. de A. N.; SOUZA, G. N. de; LOPES, S. de P. Comparação analítica entre resultados da glicemia em bovinos obtidos com glicosímetro portátil vs método enzimático. Acta Scientiae Veterinariae, v. 48, 1734, 2020. Biblioteca(s): Embrapa Gado de Leite. |
|    |
2. |  | CHENARD, M. G.; VALLE, M. D.; CUNHA, I. M. da; ALENCAR, N. X. de; LESSA, D. A. B.; SOUZA, G. N. de; CUNHA, N. C. da; CARVALHO, V. de A. N.; CALDAS, S. A.; HELAYEL, M. A. Validation of a portable glucose meter in blood glucose measurement in normoglycemic goats induced to hypoglycemia and hyperglycemia. Small Ruminant Research, v. 214, 106741, 2022. Biblioteca(s): Embrapa Gado de Leite. |
|    |
Registros recuperados : 2 | |
|
|
Registro Completo
Biblioteca(s): |
Embrapa Gado de Leite. |
Data corrente: |
11/08/2021 |
Data da última atualização: |
11/08/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
B - 1 |
Autoria: |
HELAYEL, M. A.; CUNHA, N. C. da; MORON, S. E.; SILVA, P. C. A. R. da; UNHA, I. M. da; CHENARD, M. G.; CARVALHO, V. de A. N.; SOUZA, G. N. de; LOPES, S. de P. |
Afiliação: |
MICHEL ABDALLA HELAYEL, Universidade Federal Fluminense; NATHALIE COSTA DA CUNHA, Universidade Federal Fluminense; SANDRO ESTEVAM MORON, Universidade Federal do Tocantins; PAULO CÉSAR AMARAL RIBEIRO DA SILVA, Universidade Federal Fluminense; ISABELLE MAGALHÃES DA CUNHA, Universidade Federal Fluminense; MARINA GALINDO CHENARD, Universidade Federal Fluminense; VIVIAN DE ASSUNÇÃO NOGUEIRA CARVALHO, Universidade Federal Rural do Rio de Janeiro; GUILHERME NUNES DE SOUZA, CNPGL- no artigo consta: Guilherme de Souza Nunes; SAMARA DE PAULA LOPES, Universidade Federal Rural do Rio de Janeiro. |
Título: |
Comparação analítica entre resultados da glicemia em bovinos obtidos com glicosímetro portátil vs método enzimático. |
Ano de publicação: |
2020 |
Fonte/Imprenta: |
Acta Scientiae Veterinariae, v. 48, 1734, 2020. |
DOI: |
https://doi.org/10.22456/1679-9216.102954 |
Idioma: |
Português |
Conteúdo: |
Changes in glycemic levels can negatively affect the body. Several techniques for the measurement of blood glucose have been described, but the enzymatic method is considered standard and more accurate in both humans and animals. The College of American Pathologists recommends the use of portable glucometers (PGs), which are routinely used in human medicine because this is an easy, relatively inexpensive method that delivers results quickly. The aim of this study was to compare the results of the measurement of blood glucose in cattle obtained using portable Accu-Check® glucometer with the enzymatic method (EM), which is still considered standard. |
Palavras-Chave: |
Enzymatic method; Glicemia; Glicosímetro; Glucometer; Glycemia; Livestock animals; Método enzimático. |
Thesagro: |
Bovino; Metabolismo. |
Thesaurus NAL: |
Metabolism. |
Categoria do assunto: |
L Ciência Animal e Produtos de Origem Animal |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/225058/1/Comparacao-analitica.pdf
|
Marc: |
LEADER 01688naa a2200349 a 4500 001 2133457 005 2021-08-11 008 2020 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.22456/1679-9216.102954$2DOI 100 1 $aHELAYEL, M. A. 245 $aComparação analítica entre resultados da glicemia em bovinos obtidos com glicosímetro portátil vs método enzimático.$h[electronic resource] 260 $c2020 520 $aChanges in glycemic levels can negatively affect the body. Several techniques for the measurement of blood glucose have been described, but the enzymatic method is considered standard and more accurate in both humans and animals. The College of American Pathologists recommends the use of portable glucometers (PGs), which are routinely used in human medicine because this is an easy, relatively inexpensive method that delivers results quickly. The aim of this study was to compare the results of the measurement of blood glucose in cattle obtained using portable Accu-Check® glucometer with the enzymatic method (EM), which is still considered standard. 650 $aMetabolism 650 $aBovino 650 $aMetabolismo 653 $aEnzymatic method 653 $aGlicemia 653 $aGlicosímetro 653 $aGlucometer 653 $aGlycemia 653 $aLivestock animals 653 $aMétodo enzimático 700 1 $aCUNHA, N. C. da 700 1 $aMORON, S. E. 700 1 $aSILVA, P. C. A. R. da 700 1 $aUNHA, I. M. da 700 1 $aCHENARD, M. G. 700 1 $aCARVALHO, V. de A. N. 700 1 $aSOUZA, G. N. de 700 1 $aLOPES, S. de P. 773 $tActa Scientiae Veterinariae$gv. 48, 1734, 2020.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Gado de Leite (CNPGL) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|