|
|
Registros recuperados : 56 | |
8. | | PASTORE, M. R.; SPRICIGO, P. C.; FERREIRA, M. D. Conservação pós-colheita de gérberas revestidas com cera de canaúba comercial nanoparticulada. In: JORNADA CIENTÍFICA - EMBRAPA SÃO CARLOS, 5., 2013, São Carlos, SP. Anais... São Carlos, SP: Embrapa Pecuária Sudeste: Embrapa Instrumentação , 2013. p. 24 Editado por Ana Rita de Araújo Nogueira, Simone Cristina Méo Niciura. (Embrapa Pecuária Sudeste. Documentos, 110). Biblioteca(s): Embrapa Instrumentação. |
| |
9. | | PASTORE, M. R.; SPRICIGO, P. C.; FERREIRA, M. D. Conservação pós-colheita de gérberas revestidas com cera de carnaúba nanoparticulada. In: JORNADA CIENTÍFICA - EMBRAPA SÃO CARLOS, 4., 2012, São Carlos, SP. Anais... São Carlos: Embrapa Instrumentação: Embrapa Pecuária Sudeste, 2012. p. 115. Editores técnicos: João de Mendonça Naime, Lucimara Aparecida Forato, Maria Alice Martins, Ladislau Marcelino Rabello, Rubens Bernardes Filho. (Embrapa Instrumentação. Documentos, 56) Biblioteca(s): Embrapa Instrumentação. |
| |
13. | | SPRICIGO, P. C.; FERREIRA, M. D.; NICOLAU, M.; FRUETT, F. Medição de impactos durante a pós-colheita de frutas utilizando duas esferas instrumentadas. In: INAMASU, R. Y.; NAIME, J. de M.; RESENDE, A. V. de; BASSOI, L. H.; BERNARDI, A. de C. (Ed.). Agricultura de precisão: um novo olhar. São Carlos, SP: Embrapa Instrumentação, 2011. p. 87-90. Biblioteca(s): Embrapa Instrumentação. |
| |
17. | | PILON, L.; SPRICIGO, P. C.; MOURA, M. R.; MATTOSO, L. H. C.; FERREIRA, M. D. Efeitos de revestimento à base de nanopartículas de quitosana na atividade enzimática de maçãs minimamente processadas. In: WORKSHOP DA REDE DE NANOTECNOLOGIA APLICADA AO AGRONEGÓCIO, 7.; ESCOLA DE NANOTECNOLOGIA, 3., 2013, São Carlos, SP. Anais... São Carlos, SP: Embrapa Instrumentação, 2013. p. 94-96 Editores: Maria Alice Martins, Odílio Benedito Garrido de Assis, Caue Ribeiro, Luiz Henrique Capparelli Mattoso. CD-ROM. Editores: Maria Alice Martins, Odílio Benedito Garrido de Assis, Caue Ribeiro, Luiz Henrique Capparelli Mattoso. Biblioteca(s): Embrapa Instrumentação. |
| |
18. | | PILON, L.; SPRICIGO, P. C.; MOURA, M. R.; MATTOSO, L. H. C.; FERREIRA, M. D. Evaluacion del pardeamiento enzimático de manzanas minimamente procesadas recubiertas com nanopartículas de quitosano. In: CONGRESO IBEROAMERICANO DE TECNOLOGIA POSTCOSECHA Y AGROEXPORTACIONES, 7., 2012, La Plata, Argentina. Resumos...La Plata, Argentina: AITEP, 2012. 1 CD-ROM. não paginado. Biblioteca(s): Embrapa Instrumentação. |
| |
20. | | PILON, L.; SPRICIGO, P. C.; MOURA, M. R.; MATTOSO, L. H. C.; FERREIRA, M. D. Efectos de los revestimientos comestibles a base de nanopartículas de quitosano em la composición gaseosa de manzanas minimamente procesadas. In: CONGRESO IBEROAMERICANO DE TECNOLOGIA POSTCOSECHA Y AGROEXPORTACIONES, 7., 2012, La Plata, Argentina. Resumos...La Plata, Argentina: AITEP, 2012. 1 CD-ROM. não paginado. Biblioteca(s): Embrapa Instrumentação. |
| |
Registros recuperados : 56 | |
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Instrumentação. Para informações adicionais entre em contato com cnpdia.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Instrumentação. |
Data corrente: |
27/08/2020 |
Data da última atualização: |
16/08/2022 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 2 |
Autoria: |
BORBA, K. R.; SPRICIGO, P. C.; AYKAS, D. P.; FOSCHINI, M. M.; COLNAGO, L. A.; FERREIRA, M. D. |
Afiliação: |
MILENE CORSO MITSUYUKI, CNPDIA; LUIZ ALBERTO COLNAGO, CNPDIA; MARCOS DAVID FERREIRA, CNPDIA. |
Título: |
Non-invasive quantification of vitamin C, citric acid, and sugar in "Valência" oranges using infrared spectroscopies. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Journal of Food Science and Technology,v. 58, n. 2 2021. |
Páginas: |
731-738 |
ISSN: |
0022-1155 |
DOI: |
https://doi.org/10.1007/s13197-020-04589-x |
Idioma: |
Inglês |
Conteúdo: |
Near (NIR) and mid (MIR) infrared spectroscopies have been studied as potential methods for non-destructive analyses of the fresh fruits quality. In this study, vitamin C, citric acid, total and reducing sugar content in ‘Valência’ oranges were evaluated using NIR and MIR spectroscopy with multivariate analysis. The spectral data were used to build up prediction models based on PLS (Partial Least Squares) regression. For vitamin C and citric acid, both NIR (r = 0.72 and 0.77, respectively) and MIR (0.81 and 0.91, respectively) resulted in feasible models. For sugars determination the two techniques presented a strong correlation between the reference values and analytical signals, with low RMSEP and r > 0.70 (NIR: sucrose RMSEP = 12.2 and r = 0.75; glucose RMSEP = 6.77 and r = 0.82; fructose RMSEP = 5.07 and r = 0.81; total sugar RMSEP = 12.1 and r = 0.80; reducing sugar RMSEP = 20.32 and r = 0.82; MIR: sucrose RMSEP = 9.47 and r = 0.80; glucose RMSEP = 6.70 and r = 0.82; fructose RMSEP = 5.20 and r = 0.81; total sugar RMSEP = 11.72 and r = 0.81; reducing sugar RMSEP = 20.42 and r = 0.81). The models developed with MIR presented lower prediction error rates than those made with NIR. Therefore, infrared techniques show applicability to determine of orange quality parameters in a non-destructive way. |
Palavras-Chave: |
Intact fruit quality; MIR; NIR; Non-destructive analyses; PLS. |
Categoria do assunto: |
-- |
Marc: |
LEADER 02242naa a2200277 a 4500 001 2124589 005 2022-08-16 008 2021 bl uuuu u00u1 u #d 022 $a0022-1155 024 7 $ahttps://doi.org/10.1007/s13197-020-04589-x$2DOI 100 1 $aBORBA, K. R. 245 $aNon-invasive quantification of vitamin C, citric acid, and sugar in "Valência" oranges using infrared spectroscopies.$h[electronic resource] 260 $c2021 300 $a731-738 520 $aNear (NIR) and mid (MIR) infrared spectroscopies have been studied as potential methods for non-destructive analyses of the fresh fruits quality. In this study, vitamin C, citric acid, total and reducing sugar content in ‘Valência’ oranges were evaluated using NIR and MIR spectroscopy with multivariate analysis. The spectral data were used to build up prediction models based on PLS (Partial Least Squares) regression. For vitamin C and citric acid, both NIR (r = 0.72 and 0.77, respectively) and MIR (0.81 and 0.91, respectively) resulted in feasible models. For sugars determination the two techniques presented a strong correlation between the reference values and analytical signals, with low RMSEP and r > 0.70 (NIR: sucrose RMSEP = 12.2 and r = 0.75; glucose RMSEP = 6.77 and r = 0.82; fructose RMSEP = 5.07 and r = 0.81; total sugar RMSEP = 12.1 and r = 0.80; reducing sugar RMSEP = 20.32 and r = 0.82; MIR: sucrose RMSEP = 9.47 and r = 0.80; glucose RMSEP = 6.70 and r = 0.82; fructose RMSEP = 5.20 and r = 0.81; total sugar RMSEP = 11.72 and r = 0.81; reducing sugar RMSEP = 20.42 and r = 0.81). The models developed with MIR presented lower prediction error rates than those made with NIR. Therefore, infrared techniques show applicability to determine of orange quality parameters in a non-destructive way. 653 $aIntact fruit quality 653 $aMIR 653 $aNIR 653 $aNon-destructive analyses 653 $aPLS 700 1 $aSPRICIGO, P. C. 700 1 $aAYKAS, D. P. 700 1 $aFOSCHINI, M. M. 700 1 $aCOLNAGO, L. A. 700 1 $aFERREIRA, M. D. 773 $tJournal of Food Science and Technology,v. 58$gn. 2 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|