|
|
Registros recuperados : 9 | |
3. | | SILVA, A. B. S. da; NOGUEIRA, A. R. de A. Estratégias para a quantificação de carbono residual em amostras de alimentos por MIP OES. In: JORNADA CIENTÍFICA DA EMBRAPA SÃO CARLOS, 10., 2018, São Carlos, SP. Anais... São Carlos, SP: Embrapa Instrumentação; Embrapa Pecuária Sudeste, 2018. p.66. (Embrapa Instrumentação. Documentos, 68). Editores técnicos: Daniel Souza Corrêa, Elaine Cristina Paris, Maria Alice Martins, Paulino Ribeiro Villas Boas, Wilson Tadeu Lopes da Silva. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
4. | | SILVA, A. B. S. da; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Direct determination of TiO2 as Ti used as digestibility marker in bovine faeces by Laser-Induced Breakdown Spectroscopy (LIBS). In: COLLOQUIUM SPECTROSCOPICUM INTERNATIONALE, 40., EURO-MEDITERRANEAN SYMPOSIUM ON LIBS, 9., 2017, Pisa, Italy. Proceedings... Pisa, Italy: IUPAC, 2017. p. 52. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
5. | | HIGUERAL, J. M. de; SILVA, A. B. S. da; NOGUEIRA, A. R. de A. Uso do planejamento Doehlert no desenvolvimento de método para a otimização da decomposição de carcaça de ovinos. In: JORNADA CIENTÍFICA DA EMBRAPA SÃO CARLOS, 10., 2018, São Carlos, SP. Anais... São Carlos, SP: Embrapa Instrumentação; Embrapa Pecuária Sudeste, 2018. p.56. (Embrapa Instrumentação. Documentos, 68). Editores técnicos: Daniel Souza Corrêa, Elaine Cristina Paris, Maria Alice Martins, Paulino Ribeiro Villas Boas, Wilson Tadeu Lopes da Silva. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
7. | | HIGUERA, J. M.; SILVA, A. B. S. da; HENRIQUE, W.; ESTEVES, S. N.; BARIONI JUNIOR, W.; NOGUEIRA, A. R. de A. Cruzamento genético e manejo nutricional em ovinos: efeito na composição mineral de diversos componentes corporais. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 19., 2018, Caldas Novas, GO; CONGRESSO IBEROAMERICANO DE QUÍMICA ANALÍTICA, 7., Caldas Novas, GO. Anais... Caldas Novas,GO: ENQA; CIAQA, 2018. p.1148. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
8. | | MARCANO DE HIGUERA, J.; SILVA, A. B. S. da; HENRIQUE, W.; ESTEVES, S. N.; BARIONI JUNIOR, W.; DONATI, G. L.; NOGUEIRA, A. R. de A. Effect of genetic crossing and nutritional management on the mineral composition of carcass, blood, leather, and viscera of sheep. Biological Trace Element Research, jan. 2021. p.4133-4144. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
9. | | MACHADO, R. C.; SILVA, A. B. S. da; ANDRADE, D. F. de; PINHEIRO, F. C.; WILLIAMS, C. B.; DONATI, G. L.; NOGUEIRA, A. R. de A.; PEREIRA FILHO, E. R. Alternative approaches applied to inductively coupled plasma techniques: multi-flow and two-flow calibration. Journal of the Brazilian Chemical Society, v.32, n.4, 2021. p.842-851. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 9 | |
|
|
Registro Completo
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
06/07/2021 |
Data da última atualização: |
28/09/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 2 |
Autoria: |
MACHADO, R. C.; SILVA, A. B. S. da; ANDRADE, D. F. de; PINHEIRO, F. C.; WILLIAMS, C. B.; DONATI, G. L.; NOGUEIRA, A. R. de A.; PEREIRA FILHO, E. R. |
Afiliação: |
RAQUEL CARDOSO MACHADO, UFSCAR; ANA BEATRIZ SANTOS DA SILVA, UFSCAR; DANIEL FERNANDES DE ANDRADE, UFSCAR; FERNANDA COSTA PINHEIRO, UFSCAR; CHARLES B. WILLIAMS, Davidson College; GEORGE LUIS DONATI, Wake Forest University; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; EDENIR RODRIGUES PEREIRA FILHO, UFSCAR. |
Título: |
Alternative approaches applied to inductively coupled plasma techniques: multi-flow and two-flow calibration. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Journal of the Brazilian Chemical Society, v.32, n.4, 2021. |
Páginas: |
p.842-851. |
ISSN: |
0103-5053 |
DOI: |
https://dx.doi.org/10.21577/0103-5053.20200235 |
Idioma: |
Inglês |
Conteúdo: |
Multi-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) to analyze different and complexmatrix samples. Al, As, Cd, Cr, Cu, Mn, Pb, and Zn were determined by ICP OES, while As, Cd, Co, Cu, Hg, Mo, Mn, Ni, Se, Sb, Pb, and V were determined by ICP-MS. MFC results were compared with those obtained using external standard calibration (EC) for both techniques and in all cases, MFC showed equal or superior accuracy (recoveries between 80-120%) compared to EC, and lower relative standard deviation (RSDs < 10%). Several tests were also performed using only two nebulization gas flows to build linear models for calibration (called two-flow calibration, TFC) and the accurate results (recoveries ranged from 80 to 110% for ICP OES and from 81 to 102% for ICP-MS) suggests that this strategy can be also applied, resulting in a method with high sample throughput. |
Palavras-Chave: |
Calibration strategy; ICP OES; ICP-MS; Matrix effects; Nebulization gas. |
Categoria do assunto: |
W Química e Física |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/224314/1/Alternative-Approaches-Applied.pdf
|
Marc: |
LEADER 02162naa a2200301 a 4500 001 2132812 005 2021-09-28 008 2021 bl uuuu u00u1 u #d 022 $a0103-5053 024 7 $ahttps://dx.doi.org/10.21577/0103-5053.20200235$2DOI 100 1 $aMACHADO, R. C. 245 $aAlternative approaches applied to inductively coupled plasma techniques$bmulti-flow and two-flow calibration.$h[electronic resource] 260 $c2021 300 $ap.842-851. 520 $aMulti-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) to analyze different and complexmatrix samples. Al, As, Cd, Cr, Cu, Mn, Pb, and Zn were determined by ICP OES, while As, Cd, Co, Cu, Hg, Mo, Mn, Ni, Se, Sb, Pb, and V were determined by ICP-MS. MFC results were compared with those obtained using external standard calibration (EC) for both techniques and in all cases, MFC showed equal or superior accuracy (recoveries between 80-120%) compared to EC, and lower relative standard deviation (RSDs < 10%). Several tests were also performed using only two nebulization gas flows to build linear models for calibration (called two-flow calibration, TFC) and the accurate results (recoveries ranged from 80 to 110% for ICP OES and from 81 to 102% for ICP-MS) suggests that this strategy can be also applied, resulting in a method with high sample throughput. 653 $aCalibration strategy 653 $aICP OES 653 $aICP-MS 653 $aMatrix effects 653 $aNebulization gas 700 1 $aSILVA, A. B. S. da 700 1 $aANDRADE, D. F. de 700 1 $aPINHEIRO, F. C. 700 1 $aWILLIAMS, C. B. 700 1 $aDONATI, G. L. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aPEREIRA FILHO, E. R. 773 $tJournal of the Brazilian Chemical Society$gv.32, n.4, 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|