|
|
Registro Completo |
Biblioteca(s): |
Embrapa Unidades Centrais. |
Data corrente: |
29/05/2018 |
Data da última atualização: |
29/05/2018 |
Autoria: |
SILVA, E. G.; PESSOA, G. T.; MOURA, L. S.; GUERRA, P. C.; RODRIGUES, R. P. S.; SOUSA, F. C. A.; AMBRÓSIO, C. E.; ALVES, F. R. |
Afiliação: |
Elzivânia G. Silva, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Gerson T. Pessoa, Serviço de Diagnóstico por Imagem do Hospital Veterinário Universitário/UFPI; Laecio S. Moura, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Porfírio C. Guerra, Departamento das Clínicas/Universidade Estadual do Maranhão - UEMA; Renan P. S. Rodrigues, Pós-Graduação em Ciência Animal/Universidade Federal do Piauí - UFPI; Francisco C. A. Sousa, Departamento de Medicina/Universidade Estadual do Piauí - UESPI; Carlos E. Ambrósio, Departamento de Medicina Veterinária/Universidade de São Paulo - USP; Flávio R. Alves, Departamento de Morfofisiologia Veterinária/UFPI. |
Título: |
Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs. |
Ano de publicação: |
2018 |
Fonte/Imprenta: |
Pesquisa Veterinária Brasileira, Rio de Janeiro, v. 38, n. 3, p. 565-571, março, 2018 |
Idioma: |
Inglês |
Notas: |
Título em português: Avaliação biométrica, ultrassonográfica em modo-B e por Doppler colorido ocular de cães hígidos. |
Conteúdo: |
B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies. MenosB-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler vel... Mostrar Tudo |
Palavras-Chave: |
B-mode; Bulbo ocular; Cão hígido; Doppler colorido ocular; Doppler ultrasound; Doppler velocimetry; Dopplervelocimetria; Eyeball; Ultrassonografia. |
Thesagro: |
Biometria; Cão. |
Thesaurus Nal: |
Biometry; Dogs; Hemodynamics; Ophthalmology. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/177793/1/Biometric-B-mode-and-color-Doppler-ultrasound.pdf
|
Marc: |
LEADER 03392naa a2200397 a 4500 001 2092022 005 2018-05-29 008 2018 bl uuuu u00u1 u #d 100 1 $aSILVA, E. G. 245 $aBiometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs.$h[electronic resource] 260 $c2018 500 $aTítulo em português: Avaliação biométrica, ultrassonográfica em modo-B e por Doppler colorido ocular de cães hígidos. 520 $aB-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left ye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies. 650 $aBiometry 650 $aDogs 650 $aHemodynamics 650 $aOphthalmology 650 $aBiometria 650 $aCão 653 $aB-mode 653 $aBulbo ocular 653 $aCão hígido 653 $aDoppler colorido ocular 653 $aDoppler ultrasound 653 $aDoppler velocimetry 653 $aDopplervelocimetria 653 $aEyeball 653 $aUltrassonografia 700 1 $aPESSOA, G. T. 700 1 $aMOURA, L. S. 700 1 $aGUERRA, P. C. 700 1 $aRODRIGUES, R. P. S. 700 1 $aSOUSA, F. C. A. 700 1 $aAMBRÓSIO, C. E. 700 1 $aALVES, F. R. 773 $tPesquisa Veterinária Brasileira, Rio de Janeiro$gv. 38, n. 3, p. 565-571, março, 2018
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Unidades Centrais (AI-SEDE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registro Completo
Biblioteca(s): |
Embrapa Cerrados. |
Data corrente: |
17/03/2010 |
Data da última atualização: |
20/02/2013 |
Tipo da produção científica: |
Boletim de Pesquisa e Desenvolvimento |
Autoria: |
MORAES NETO, S. P. de; TELES, R. F.; RODRIGUES, T. O.; VALE, A. T. do; SOUZA, M. R. |
Afiliação: |
SEBASTIAO PIRES DE MORAES NETO, CPAC; RICARDO FAUSTINO TELES, FUNTEC/DF; THIAGO OLIVEIRA RODRIGUES, FUNTEC/DF; AILTON TEIXEIRA DO VALE, UnB; MARIO RABELO DE SOUZA, IBAMA. |
Título: |
Propriedades físicas da madeira de cinco procedências de pinus caribaea var. hondurensis implantadas no cerrado do Distrito Federal, DF |
Ano de publicação: |
2009 |
Fonte/Imprenta: |
Planaltina, DF : Embrapa Cerrados, 2009. |
Descrição Física: |
19 p. |
Série: |
(Embrapa Cerrados. Boletim de pesquisa e desenvolvimento, 243). |
Idioma: |
Português |
Conteúdo: |
Pinus caribaea var. hondurensis é uma espécie tropical que ocorre naturalmente nas terras baixas da América Central e no Leste do México. No Brasil, existem plantios comerciais dessa espécie para fi ns de serraria, resina e celulose, especialmente. Para seu uso em estruturas, existe a necessidade do conhecimento de suas propriedades físicas e mecânicas. As propriedades físicas variam, signifi cativamente, entre espécies, entre árvores de uma mesma espécie e, mesmo, entre diferentes partes de uma mesma árvore. Este trabalho tem como objetivo analisar as variações das propriedades físicas da madeira de cinco procedências de P. caribaea var. hondurensis. Para tanto, amostras foram retiradas para teste quando as árvores tinham 23 anos de idade. A procedência de El Porvenir apresentou maior massa específica básica e a de Los Limones, a menor. Essas duas procedências mostraram os menores coeficientes anisotrópicos. |
Palavras-Chave: |
Massa específica básica; Retrabilidade. |
Thesagro: |
Cerrado; Madeira; Plantio. |
Thesaurus NAL: |
Pinus; Pinus caribaea var. hondurensis; Wood. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/CPAC-2010/31296/1/bolpd-243.pdf
|
Marc: |
LEADER 01790nam a2200277 a 4500 001 1661552 005 2013-02-20 008 2009 bl uuuu u0uu1 u #d 100 1 $aMORAES NETO, S. P. de 245 $aPropriedades físicas da madeira de cinco procedências de pinus caribaea var. hondurensis implantadas no cerrado do Distrito Federal, DF 260 $aPlanaltina, DF : Embrapa Cerrados$c2009 300 $c19 p. 490 $a(Embrapa Cerrados. Boletim de pesquisa e desenvolvimento, 243). 520 $aPinus caribaea var. hondurensis é uma espécie tropical que ocorre naturalmente nas terras baixas da América Central e no Leste do México. No Brasil, existem plantios comerciais dessa espécie para fi ns de serraria, resina e celulose, especialmente. Para seu uso em estruturas, existe a necessidade do conhecimento de suas propriedades físicas e mecânicas. As propriedades físicas variam, signifi cativamente, entre espécies, entre árvores de uma mesma espécie e, mesmo, entre diferentes partes de uma mesma árvore. Este trabalho tem como objetivo analisar as variações das propriedades físicas da madeira de cinco procedências de P. caribaea var. hondurensis. Para tanto, amostras foram retiradas para teste quando as árvores tinham 23 anos de idade. A procedência de El Porvenir apresentou maior massa específica básica e a de Los Limones, a menor. Essas duas procedências mostraram os menores coeficientes anisotrópicos. 650 $aPinus 650 $aPinus caribaea var. hondurensis 650 $aWood 650 $aCerrado 650 $aMadeira 650 $aPlantio 653 $aMassa específica básica 653 $aRetrabilidade 700 1 $aTELES, R. F. 700 1 $aRODRIGUES, T. O. 700 1 $aVALE, A. T. do 700 1 $aSOUZA, M. R.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Cerrados (CPAC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|