|
|
Registros recuperados : 17 | |
4. | | OLIVEIRA, O. N. C. de; OUNKHIR, S.; SAQUI, D.; RAMOS JUNIOR, A. V.; SANTOS, S. A. Proposta de avaliação do cavalo Pantaneiro por meio de visão computacional. In: EVENTO DE INICIAÇÃO CIENTÍFICA DO PANTANAL, 7., 2019, Corumbá. Resumos... Brasília, DF: Embrapa, 2019. p. 18. Biblioteca(s): Embrapa Pantanal. |
| |
7. | | LEITE, F. L.; BORATO, C. E.; OLIVEIRA, O. N.; HERRMANN, P. S. P.; FROMMER, J. E.; MATTOSO, L. H. Atomic force spectroscopy as a tool to study thin film og conductive polymer in solution with different pHs. LATIN AMERICAM SYMPOSIUM ON SCANNING PROBE MICROSCOPY, 3., 2005, Ouro Preto. [Anais eletrônicos...]. Ouro Preto: SBMN, 2005. 1 CD-ROM. Biblioteca(s): Embrapa Instrumentação. |
| |
8. | | OUNKHIR, S.; OLIVEIRA, O. N. C. de; KOIKE, C. Y.; GRASSI, M. J. S.; SAQUI, D.; SANTOS, S. A. Análise de algoritmos de aprendizado de máquina para classificação do padrão racial do cavalo pantaneiro. In: EVENTO DE INICIAÇÃO CIENTÍFICA DO PANTANAL, 7., 2019, Corumbá. Resumos... Brasília, DF: Embrapa, 2019. p. 8. Biblioteca(s): Embrapa Pantanal. |
| |
9. | | LEITE, F. L.; SIMÕES, M. L.; HERRMANN, P. S. P.; MARTIN NETO, L.; MATTOSO, L. H. C.; OLIVEIRA, O. N. Evidence of conducting islands on polyaniline films: charge nanocarriers. In: ENCONTRO DA SOCIEDADE BRASILEIRA DE PESQUISA EM MATERIAIS - SbpMat, 6., 2007, Natal; BRAZILIAN MRS MEETING, 6., 2007, Natal. Abstracts... Natal: SBMat, 2007. 1 CD-ROM. Não paginado. Biblioteca(s): Embrapa Instrumentação. |
| |
11. | | LEITE, F. L.; PATERNO, L. G.; BRUGNOLLO, E. D.; BORATO, C. E.; OLIVEIRA, O. N.; HERRMANN, L. H. C. Studies of polymer adsorption on to solid substrates by atomic force microscopy (AFM): Influences of doping process. In: ENCONTRO DA SBPMat, 3., Foz do Iguaçu, 2004. Resumos... Foz do Iguaçu, 2004. Biblioteca(s): Embrapa Instrumentação. |
| |
12. | | RIBEIRO, C. C. A.; OLIVEIRA, O. N. C. de; GRASSI, M. J. S.; SAQUI, D.; PALHARES, J. C. P.; OLIVEIRA, M. D. de; SANTOS, S. A. Aplicativo para previsão de disponibilidade de água de bebedouros para dessedentação animal. In: EVENTO DE INICIAÇÃO CIENTÍFICA DO PANTANAL, 7., 2019, Corumbá. Resumos... Brasília, DF: Embrapa, 2019. p. 9. Biblioteca(s): Embrapa Pantanal. |
| |
14. | | LEITE, F. L.; HERRMANN, P. S. P.; MATTOSO, L. H. C.; SILVA, W. T. L. da; BORATO, C. E.; OLIVEIRA, O. N. Atomic force spectroscopy (AFS) on poly(o-ethoxyaniline) nanostructured. In: [Latin American Symposium on Scanning Probe Microscopy Program] - LASPM, 4., 2007, La Plata. [Anais...] [s. l. : s. n.], 2007. Pôster 27. Biblioteca(s): Embrapa Instrumentação. |
| |
15. | | SOARES, A. C.; SOARES, J. C.; PASCHOALIN, R. T.; RODRIGUES, V. C.; MELENDEZ, M. E.; REIS, R. M.; CARVALHO, A. L.; MATTOSO, L. H. C.; OLIVEIRA, O. N. Immunosensors containing solution blow spun fibers of poly(lactic acid) to detect p53 biomarker. Materials Science & Engineering C, v. 115, 2020. 1-10 Biblioteca(s): Embrapa Instrumentação. |
| |
16. | | SANTOS, D. M. dos; MIGLIORINI, F. L.; COATRINI-SOARES, A.; SOARES, J.; MATTOSO, L. H. C.; OLIVEIRA, O. N.; CORREA, D. S. Low-cost paper-based sensors modified with curcumin for the detection of ochratoxin a in beverages. Sensors and Actuators Reports, v. 7, 100184, 2024. 11 p. Biblioteca(s): Embrapa Instrumentação. |
| |
17. | | HERRMANN, P. S. de P.; MASCARENHAS, Y. P.; POLIKARPOV, I.; BALLESTERO, M. R. M.; OLIVEIRA NETO, M. de; LEITE, F. de L.; MATTOSO, L. H. C.; OLIVEIRA, O. N. de. Nanoscale conformational ordering on poly(alkoxyanilines): fractal behavior and thin films formation mechanism. In: ENCONTRO DA SBPMAT, 5.; BRAZILIAN MRS MEETING, 5TH., 2006, Florianópolis. Final program... Florianópolis: [s. n.], 2006. p. 111. 1CD-ROM. Biblioteca(s): Embrapa Instrumentação. |
| |
Registros recuperados : 17 | |
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Instrumentação. Para informações adicionais entre em contato com cnpdia.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Instrumentação. |
Data corrente: |
05/06/2020 |
Data da última atualização: |
16/08/2022 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 1 |
Autoria: |
SOARES, A. C.; SOARES, J. C.; PASCHOALIN, R. T.; RODRIGUES, V. C.; MELENDEZ, M. E.; REIS, R. M.; CARVALHO, A. L.; MATTOSO, L. H. C.; OLIVEIRA, O. N. |
Afiliação: |
LUIZ HENRIQUE CAPPARELLI MATTOSO, CNPDIA. |
Título: |
Immunosensors containing solution blow spun fibers of poly(lactic acid) to detect p53 biomarker. |
Ano de publicação: |
2020 |
Fonte/Imprenta: |
Materials Science & Engineering C, v. 115, 2020. |
Páginas: |
1-10 |
ISSN: |
0928-4931 |
DOI: |
https://doi.org/10.1016/j.msec.2020.111120 |
Idioma: |
Inglês |
Conteúdo: |
This paper reports on biosensors made with a matrix of polylactic acid (PLA) fibers, which are suitable for immobilization of the anti-p53 active layer for detection of p53 biomarker. The PLA fibers were produced with solution blow spinning, a method that is advantageous for its simplicity and possibility to tune the fiber properties. For the biosensors, the optimized time to deposit the fibers was 60 s, with which detection of p53 could be achieved with the limit of detection of 11 pg/mL using electrical impedance spectroscopy. This sensitivity is also sufficient to detect the p53 biomarker in patient samples, which was confirmed by distinguishing samples from cell lines with distinct p53 concentrations in a plot where the impedance spectra were visualized with the interactive document mapping (IDMAP) technique. The high sensitivity and selectivity of the biosensors may be attributed to the specific interaction between the active layer and p53 modeled with a Langmuir-Freundlich and Freundlich isotherms and inferred from the analysis of the vibrational bands at 1550, 1650 and 1757 cm−1 using polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). The successful immobilization of the active layer is evidence that the approach based on solution blown spun fibers may be replicated to other types of biosensors. |
Palavras-Chave: |
Immunosensor; PLA fibers; Solution blow spinning. |
Categoria do assunto: |
-- |
Marc: |
LEADER 02209naa a2200289 a 4500 001 2123069 005 2022-08-16 008 2020 bl uuuu u00u1 u #d 022 $a0928-4931 024 7 $ahttps://doi.org/10.1016/j.msec.2020.111120$2DOI 100 1 $aSOARES, A. C. 245 $aImmunosensors containing solution blow spun fibers of poly(lactic acid) to detect p53 biomarker.$h[electronic resource] 260 $c2020 300 $a1-10 520 $aThis paper reports on biosensors made with a matrix of polylactic acid (PLA) fibers, which are suitable for immobilization of the anti-p53 active layer for detection of p53 biomarker. The PLA fibers were produced with solution blow spinning, a method that is advantageous for its simplicity and possibility to tune the fiber properties. For the biosensors, the optimized time to deposit the fibers was 60 s, with which detection of p53 could be achieved with the limit of detection of 11 pg/mL using electrical impedance spectroscopy. This sensitivity is also sufficient to detect the p53 biomarker in patient samples, which was confirmed by distinguishing samples from cell lines with distinct p53 concentrations in a plot where the impedance spectra were visualized with the interactive document mapping (IDMAP) technique. The high sensitivity and selectivity of the biosensors may be attributed to the specific interaction between the active layer and p53 modeled with a Langmuir-Freundlich and Freundlich isotherms and inferred from the analysis of the vibrational bands at 1550, 1650 and 1757 cm−1 using polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS). The successful immobilization of the active layer is evidence that the approach based on solution blown spun fibers may be replicated to other types of biosensors. 653 $aImmunosensor 653 $aPLA fibers 653 $aSolution blow spinning 700 1 $aSOARES, J. C. 700 1 $aPASCHOALIN, R. T. 700 1 $aRODRIGUES, V. C. 700 1 $aMELENDEZ, M. E. 700 1 $aREIS, R. M. 700 1 $aCARVALHO, A. L. 700 1 $aMATTOSO, L. H. C. 700 1 $aOLIVEIRA, O. N. 773 $tMaterials Science & Engineering C$gv. 115, 2020.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|