|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
09/11/2006 |
Data da última atualização: |
13/06/2023 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
NOGUEIRA, A. R. de A.; MOTA, A. V. C.; LEMOS, S. G.; PARRA, A.; ALONSO, J. |
Afiliação: |
ANA RITA DE ARAUJO NOGUEIRA, CPPSE; ARIEL VICENTE CAMARNADO MOTA, UFSCar/SÃO CARLOS, SP.; SHERLAN G. LEMOS, UFSCar/SÃO CARLOS, SP.; ALEIX PARRA, UNIVIERSITAT DE BARCELONA; JULIAN ALONSO, UNIVIERSITAT DE BARCELONA. |
Título: |
Flow injection potentiometric system for ATP determination in pharmaceutical samples using experimental design. |
Ano de publicação: |
2006 |
Fonte/Imprenta: |
In: INTERNATIONAL CONFERENCE FLOW ANALYSIS, 10., 2006, Porto. Proceedings... Porto: IAFA, 2006. |
Páginas: |
p. 183. |
Idioma: |
Inglês |
Conteúdo: |
To identify thenítrogen transportation formsand attaín lhe control mechanísm, lhe amount of free amino acids in different parts of lhe plant has to be determined. An automatic, fast and relíable procedure multícomutated flow system [1] has been developed for spectrophotometríc analysís of totalamíno acíds in plant material. The method is suitable for routine analysís for a largenumber of samples of plant material. The flow manifold was designed with computer- controlled three-way solenoíd valves forindependent handlíng of sample and reagent solutions and a data acquisition system from a spectrophotometer, employed for sígnal measurements. The software for system control was performed bya program with use of a LabView platform (Nationallntrumentsl [2]. The detection reaction was based on the complexation of amino functíonal groups ofamino acids by nínhydrin. It reacts with free a-amino groups, producing the colored ninhydrin chromophore called Ruhemann's purple (RP) IAmax = 570 nm; (= 22000) [3]. The proposed detection system shows a linear range concentration upto 2.0 x 10-3 mal L-1 wíth coefficient of variation of 1.1% (n = 10). Detection limíts wereestimated as 2.8 x 10-3 mal L-1 at 99.7% confidence level for total amino acids, and a mean sampling rate of 30 determínQtions per hour was achieved. |
Palavras-Chave: |
Flow system; Plant; Spectrometric. |
Thesaurus Nal: |
amino acids. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02020nam a2200217 a 4500 001 1047587 005 2023-06-13 008 2006 bl uuuu u00u1 u #d 100 1 $aNOGUEIRA, A. R. de A. 245 $aFlow injection potentiometric system for ATP determination in pharmaceutical samples using experimental design.$h[electronic resource] 260 $aIn: INTERNATIONAL CONFERENCE FLOW ANALYSIS, 10., 2006, Porto. Proceedings... Porto: IAFA$c2006 300 $ap. 183. 520 $aTo identify thenítrogen transportation formsand attaín lhe control mechanísm, lhe amount of free amino acids in different parts of lhe plant has to be determined. An automatic, fast and relíable procedure multícomutated flow system [1] has been developed for spectrophotometríc analysís of totalamíno acíds in plant material. The method is suitable for routine analysís for a largenumber of samples of plant material. The flow manifold was designed with computer- controlled three-way solenoíd valves forindependent handlíng of sample and reagent solutions and a data acquisition system from a spectrophotometer, employed for sígnal measurements. The software for system control was performed bya program with use of a LabView platform (Nationallntrumentsl [2]. The detection reaction was based on the complexation of amino functíonal groups ofamino acids by nínhydrin. It reacts with free a-amino groups, producing the colored ninhydrin chromophore called Ruhemann's purple (RP) IAmax = 570 nm; (= 22000) [3]. The proposed detection system shows a linear range concentration upto 2.0 x 10-3 mal L-1 wíth coefficient of variation of 1.1% (n = 10). Detection limíts wereestimated as 2.8 x 10-3 mal L-1 at 99.7% confidence level for total amino acids, and a mean sampling rate of 30 determínQtions per hour was achieved. 650 $aamino acids 653 $aFlow system 653 $aPlant 653 $aSpectrometric 700 1 $aMOTA, A. V. C. 700 1 $aLEMOS, S. G. 700 1 $aPARRA, A. 700 1 $aALONSO, J.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 4 | |
2. | | COSTAMILAN, L. M.; SCHEEREN, P. L.; FELÍCIO, J. C.; MELO, M. S. de; CAMPOS, L. A. C.; DALLA NORA, T. Efetividade de genes Pm de trigo a oídio (Blumeria graminis f. sp. tritici), em 2007. Tropical Plant Pathology, Brasília, DF, v. 33, p. S201, ago. 2008. Suplemento, ref MEL-009. Edição dos Resumos do XLI Congresso Brasileiro de Fitopatologia, Belo Horizonte, ago. 2008.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Trigo. |
| |
4. | | COSTAMILAN, L. M.; FELÍCIO, J. C.; MELO, M. S. DE; NORA, T. D.; SCHEEREN, P. L.; CAMPOS, L. A. C. Efetividade de genes de resistência de trigo a oídio, safra 2007. In: REUNIÃO DA COMISSÃO BRASILEIRA DE PESQUISA DE TRIGO E TRITICALE, 2., 2008, Passo Fundo. Atas e resumos... Passo Fundo: Comissão Brasileira de Pesquisa de Trigo e Triticale: Embrapa Trigo: Embrapa Transferência de Tecnologia, 2008. 3 p. 1 CD-ROM. Fitopatologia, 16. Área: Fitopatologia.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Trigo. |
| |
Registros recuperados : 4 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|