Autoria: |
CARVALHO, A. A.; MASCARENHAS, S.; PAULA, M. H. de. |
Afiliação: |
UNESP-Campus de Ilha Solteira; EMBRAPA-CNPDIA. |
Título: |
A new pulsed pyroelectric radiation dosimeter. |
Ano de publicação: |
1988 |
Fonte/Imprenta: |
In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988. |
Páginas: |
p.II-25. |
Idioma: |
Inglês |
Conteúdo: |
We describe a new type of radiation dosimeter for the diagnostic X-ray region using a pyroelectric detector. The pulsed pyroelectric radiation dosimeter (PPERD) is a system constituted by a X-ray beam commutator, a pyroelectric chamber, a pre-amplifier and an electronic peak detector. The pyroelectric chamber consists basically of a lead zirconium titanate (PZT) ceramic (17mm x 17mm and 3mm thick) on a nylon support. The chamber is evacuated to about 1mm Hg. The thickness of the detector is such that it absorbed more than 99% of the X-ray beam used in these studies. The pyroelectric element itself absorbs a X-ray pulse and provides a voltage proportional to the energy absorbed. The PPERD has the following characteristics for diagnostic X-ray beams: 1) it responds linearly to the radiation intensity for a given radiation spectrum; 2) it responds linearly to the radiatin energy fluence rate; 3) the pyroelectric chamber is simple to construct, inexpensive and rugged; 4) the lower detection limit of energy fluence rate range and of exposure rate range are respectively 20mW/m2 and 9,0.10E-6C.KgE-1 sE-1 (35mR/s). |
Palavras-Chave: |
Dosimeter; Pulsed; Pyroelectric; Radiation. |
Categoria do assunto: |
-- |
Marc: |
LEADER 01716naa a2200205 a 4500 001 1026547 005 2010-03-09 008 1988 bl --- 0-- u #d 100 1 $aCARVALHO, A. A. 245 $aA new pulsed pyroelectric radiation dosimeter. 260 $c1988 300 $ap.II-25. 520 $aWe describe a new type of radiation dosimeter for the diagnostic X-ray region using a pyroelectric detector. The pulsed pyroelectric radiation dosimeter (PPERD) is a system constituted by a X-ray beam commutator, a pyroelectric chamber, a pre-amplifier and an electronic peak detector. The pyroelectric chamber consists basically of a lead zirconium titanate (PZT) ceramic (17mm x 17mm and 3mm thick) on a nylon support. The chamber is evacuated to about 1mm Hg. The thickness of the detector is such that it absorbed more than 99% of the X-ray beam used in these studies. The pyroelectric element itself absorbs a X-ray pulse and provides a voltage proportional to the energy absorbed. The PPERD has the following characteristics for diagnostic X-ray beams: 1) it responds linearly to the radiation intensity for a given radiation spectrum; 2) it responds linearly to the radiatin energy fluence rate; 3) the pyroelectric chamber is simple to construct, inexpensive and rugged; 4) the lower detection limit of energy fluence rate range and of exposure rate range are respectively 20mW/m2 and 9,0.10E-6C.KgE-1 sE-1 (35mR/s). 653 $aDosimeter 653 $aPulsed 653 $aPyroelectric 653 $aRadiation 700 1 $aMASCARENHAS, S. 700 1 $aPAULA, M. H. de 773 $tIn: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Agrobiologia. Para informações adicionais entre em contato com cnpab.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Agrobiologia. |
Data corrente: |
17/05/2010 |
Data da última atualização: |
01/06/2010 |
Tipo da produção científica: |
Folder/Folheto/Cartilha |
Autoria: |
AQUINO, A. M. de; ARAUJO, E. S. |
Afiliação: |
ADRIANA MARIA DE AQUINO, CNPAB; E. S. ARAUJO. |
Título: |
Minhocultura. |
Ano de publicação: |
2009 |
Fonte/Imprenta: |
Seropédica: Embrapa Agrobiologia, 2009. |
Idioma: |
Português |
Thesagro: |
Adubo Orgânico; Minhoca. |
Categoria do assunto: |
-- |
Marc: |
LEADER 00327nam a2200133 a 4500 001 1853265 005 2010-06-01 008 2009 bl uuuu u0uu1 u #d 100 1 $aAQUINO, A. M. de 245 $aMinhocultura. 260 $aSeropédica: Embrapa Agrobiologia$c2009 650 $aAdubo Orgânico 650 $aMinhoca 700 1 $aARAUJO, E. S.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Agrobiologia (CNPAB) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|