Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
04/06/2013 |
Data da última atualização: |
15/05/2023 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
SUAREZ, W. T.; PESSOA NETO, O. D.; SANTOS, V. B. dos; NOGUEIRA, A. R. de A.; FARIA, R. C.; FATIBELLO-FILHO, O.; CHAMARRO, J. A. |
Afiliação: |
WILLIAN T. SUAREZ, Universidade Federal de Viçosa; OSMUNDO D. PESSOA-NETO, Universidade Federal de São Carlos; VAGNER B. DOS SANTOS, Universidade Federal de São Carlos; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; RONALDO C. FARIA, Universidade Federal de São Carlos; ORLANDO FATIBELLO-FILHO, Universidade Federal de São Carlos; JULIÁN A. CHAMARRO, Universitat Autònoma de Barcelona. |
Título: |
A compact miniaturized flow system based on low-temperature co-fired ceramic technology coupled to led mini-photometer for determination of dipyrone in pharmaceutical formulations. |
Ano de publicação: |
2013 |
Fonte/Imprenta: |
Journal Brazilian Chemical Society, v. 24, n. 5, p. 847-855, may 2013. |
DOI: |
https://doi.org/10.5935/0103-5053.20130112 |
Idioma: |
Inglês |
Conteúdo: |
In this work, an analytical microsystem based on LTCC (low-temperature co-fired ceramic) technology with monolithic incorporation of an optical flow cell for determination of dipyrone in pharmaceuticals is described. The detection system is based on the formation of a blue chromophore between dipyrone and Fe(III) photometrically monitored at 630 nm using a lab-made LED mini-photometer constructed with a light emitting diode as a radiation source and a Si photodiode as a detector. The lab-made mini-photometer elaborated presented a good performance in regard to high signal/noise ratio, low drift and good sensitivity. The analytical curve was linear in the dipyrone concentration range from 1.0 × 10-4 to 3.5 × 10-3 mol L-1, limit of detection of 4.5 × 10-5 mol L-1 and total time of analyses of 20 s yielding an analytical frequency of 195 h-1 with a low waste generation per analysis (480 µL). |
Palavras-Chave: |
Analytical microsystems; Co-fired ceramic; Dipyrone; Flow injection; LED photometer; Low temperature. |
Categoria do assunto: |
W Química e Física |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/95364/1/PROCI-2013.00023.pdf
|
Marc: |
LEADER 01862naa a2200277 a 4500 001 1959237 005 2023-05-15 008 2013 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.5935/0103-5053.20130112$2DOI 100 1 $aSUAREZ, W. T. 245 $aA compact miniaturized flow system based on low-temperature co-fired ceramic technology coupled to led mini-photometer for determination of dipyrone in pharmaceutical formulations.$h[electronic resource] 260 $c2013 520 $aIn this work, an analytical microsystem based on LTCC (low-temperature co-fired ceramic) technology with monolithic incorporation of an optical flow cell for determination of dipyrone in pharmaceuticals is described. The detection system is based on the formation of a blue chromophore between dipyrone and Fe(III) photometrically monitored at 630 nm using a lab-made LED mini-photometer constructed with a light emitting diode as a radiation source and a Si photodiode as a detector. The lab-made mini-photometer elaborated presented a good performance in regard to high signal/noise ratio, low drift and good sensitivity. The analytical curve was linear in the dipyrone concentration range from 1.0 × 10-4 to 3.5 × 10-3 mol L-1, limit of detection of 4.5 × 10-5 mol L-1 and total time of analyses of 20 s yielding an analytical frequency of 195 h-1 with a low waste generation per analysis (480 µL). 653 $aAnalytical microsystems 653 $aCo-fired ceramic 653 $aDipyrone 653 $aFlow injection 653 $aLED photometer 653 $aLow temperature 700 1 $aPESSOA NETO, O. D. 700 1 $aSANTOS, V. B. dos 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aFARIA, R. C. 700 1 $aFATIBELLO-FILHO, O. 700 1 $aCHAMARRO, J. A. 773 $tJournal Brazilian Chemical Society$gv. 24, n. 5, p. 847-855, may 2013.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 1 | |
1. |  | SUAREZ, W. T.; PESSOA NETO, O. D.; SANTOS, V. B. dos; NOGUEIRA, A. R. de A.; FARIA, R. C.; FATIBELLO-FILHO, O.; CHAMARRO, J. A. A compact miniaturized flow system based on low-temperature co-fired ceramic technology coupled to led mini-photometer for determination of dipyrone in pharmaceutical formulations. Journal Brazilian Chemical Society, v. 24, n. 5, p. 847-855, may 2013.Tipo: Artigo em Periódico Indexado | Circulação/Nível: A - 1 |
Biblioteca(s): Embrapa Pecuária Sudeste. |
|    |
Registros recuperados : 1 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|