Autoria: |
BABOS, D. V.; GARCIA, R. H. S.; COLNAGO, L. A. |
|
Afiliação: |
LUIZ ALBERTO COLNAGO, CNPDIA. |
|
Título: |
A simple, rapid, green and non-destructive 19F time-domain NMR method for directly fluorine determination in powder of mineral supplements for cattle. |
|
Ano de publicação: |
2020 |
|
Fonte/Imprenta: |
Microchemical Journal, n.153, a. 104416, 2020. |
|
ISSN: |
0026-065X |
|
DOI: |
10.1016/j.microc.2019.104416 |
|
Idioma: |
Inglês |
|
Conteúdo: |
A simple, rapid, green and non-destructive 19 F time-domain nuclear magnetic resonance (TD NMR) method for fluorine determination directly in the powder of cattle mineral supplements is presented. The measurements were performed in a 0.49 T (18.76 MHz for 19 F) spectrometer using a 10 mm probe with 10 μs dead time. Standard samples from 0 to 21,700 mg kg −1 F were prepared diluting the appropriate amount of BaF2 in the salts Na 2CO 3 : NaCl (1:1 w/w) that are normally used in the mineral supplements. The intensity of the free induction signal (FID), measured at 10 μs after 90° pulse and the fluorine content was used in an univariate model, with a limit of detection of 388 mg kg −1 F. A partial least square model was also built using all FID data points and Fluorine content and yield a standard error of validation of 199 mg kg −1 F. Accuracy was assessed by addition / recovery tests the analysis for two mineral supplements for cattle with trueness from 81 to 120%. Therefore, this is a green (non-chemical waste), simple (minimal sample preparation), fast (20 min) alternative method for determination of F in cattle mineral supplements. |
|
Palavras-Chave: |
Direct solid analysis; Fluorine determination; Mineral supplements for cattle; Time domain nuclear magnetic resonance. |
|
Categoria do assunto: |
-- |
|
Marc: |
LEADER 01920naa a2200217 a 4500 001 2121651 005 2024-12-11 008 2020 bl uuuu u00u1 u #d 022 $a0026-065X 024 7 $a10.1016/j.microc.2019.104416$2DOI 100 1 $aBABOS, D. V. 245 $aA simple, rapid, green and non-destructive 19F time-domain NMR method for directly fluorine determination in powder of mineral supplements for cattle.$h[electronic resource] 260 $c2020 520 $aA simple, rapid, green and non-destructive 19 F time-domain nuclear magnetic resonance (TD NMR) method for fluorine determination directly in the powder of cattle mineral supplements is presented. The measurements were performed in a 0.49 T (18.76 MHz for 19 F) spectrometer using a 10 mm probe with 10 μs dead time. Standard samples from 0 to 21,700 mg kg −1 F were prepared diluting the appropriate amount of BaF2 in the salts Na 2CO 3 : NaCl (1:1 w/w) that are normally used in the mineral supplements. The intensity of the free induction signal (FID), measured at 10 μs after 90° pulse and the fluorine content was used in an univariate model, with a limit of detection of 388 mg kg −1 F. A partial least square model was also built using all FID data points and Fluorine content and yield a standard error of validation of 199 mg kg −1 F. Accuracy was assessed by addition / recovery tests the analysis for two mineral supplements for cattle with trueness from 81 to 120%. Therefore, this is a green (non-chemical waste), simple (minimal sample preparation), fast (20 min) alternative method for determination of F in cattle mineral supplements. 653 $aDirect solid analysis 653 $aFluorine determination 653 $aMineral supplements for cattle 653 $aTime domain nuclear magnetic resonance 700 1 $aGARCIA, R. H. S. 700 1 $aCOLNAGO, L. A. 773 $tMicrochemical Journal$gn.153, a. 104416, 2020.
Download
Esconder MarcMostrar Marc Completo |
|
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
|
| Registros recuperados : 39 | |
| 5. |  | GRASSI, V.; KAMOGAWA, M. Y.; MATTOSO, L. H. C. An electronic tongue for water monitoring employed flow system. In: INTERNATIONAL CONFERENCE ON FOOD AND AGRICULTURE APPLICATIONS OF NANOTECHNOLOGIES - NanoAgri, 2010, São Pedro, SP. [Anais...] São Pedro: Aptor Software, 2010. Editors: Caue Ribeiro, Odílio Benedito Garrido de Assis, Luiz Henrique Capparelli Mattoso, Sérgio Mascarenhas.| Tipo: Artigo em Anais de Congresso |
| Biblioteca(s): Embrapa Instrumentação. |
|    |
| 20. |  | CRISPINO, C. C.; KAMOGAWA, M. Y.; NOGUEIRA, A. R. de A. FI-HG-ICP OES system for simultaneous determination of As, Sb and Se. In: REUNIÃO ANUAL DA SOCIEDADE DE QUÍMICA, 27.; CONGRESO LATINO AMERICANO DE QUÍMICA, 26., 2004, Salvador, BA. Livro de resumos... Salvador: SBQ, 2004.| Tipo: Resumo em Anais de Congresso |
| Biblioteca(s): Embrapa Pecuária Sudeste. |
|    |
| Registros recuperados : 39 | |
|
| Expressão de busca inválida. Verifique!!! |
|
|