|
|
 | Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
03/12/2020 |
Data da última atualização: |
03/12/2020 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
SILVA, A. B. S.; HIGUERA, J. M.; BRAZ, C. E. M.; MACHADO, R. C.; NOGUEIRA, A. R. de A. |
Afiliação: |
Ana Beatriz S. Silva, UFSCAR; Julymar M. Higuera, UFSCAR; CARLOS EDUARDO M. BRAZ, UFSCAR; RAQUEL CARDOSO MACHADO, UFSCAR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE. |
Título: |
Evaluation of different nebulizers performance on microwave-induced plasma optical emission spectrometry. |
Ano de publicação: |
2020 |
Fonte/Imprenta: |
Spectrochimica Acta Part B, v. 168, p. 1614-1620, 105867, jun. 2020. |
DOI: |
https://doi.org/10.1016/j.sab.2020.105867 |
Idioma: |
Inglês |
Conteúdo: |
The choice of an adequate nebulizer reflects directly in the accuracy, especially when a complex matrix is analyzed in plasma techniques. To unveil the effects on fundamental parameters and analytical performance of a microwave-induced plasma optical emission spectrometry, four commercial nebulizers, Concentric, Mira Mist, OneNeb series 1, and OneNeb series 2, were evaluated. Estimated fundamental plasma parameters, excitation temperature (T), and the number of electron density (ne) indicated that the Mira Mist nebulizer afforded a plasma with the highest T and ne, but the lowest solvent transport efficiency. OneNeb series 2 showed the lowest T and ne, nonetheless the highest solvent transport efficiency. The precision was estimated in the middle of nitric acid (1% v v-1), sulfuric acid (1% v v-1), easily ionizable elements (100 mg L-1 of Ba, K, and Na), ethanol (1% v v-1), and carbon content (1000 mg L-1). The OneNeb series 2 presented the lowest RSD and LOD values in all matrices, while the concentric presented the highest RSD. The accuracy was evaluated by certified reference materials and addition and recovery experiments performed in sugarcane spirit. Considering the sensitivity improvement, solvent transport efficiency and analytical precision the OneNeb series 2 achieved superior performance. |
Palavras-Chave: |
Concentric; Crossflow; Enhanced parallel path; Optical emission spectrometry; Pneumatic nebulizer. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02110naa a2200241 a 4500 001 2127529 005 2020-12-03 008 2020 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.1016/j.sab.2020.105867$2DOI 100 1 $aSILVA, A. B. S. 245 $aEvaluation of different nebulizers performance on microwave-induced plasma optical emission spectrometry.$h[electronic resource] 260 $c2020 520 $aThe choice of an adequate nebulizer reflects directly in the accuracy, especially when a complex matrix is analyzed in plasma techniques. To unveil the effects on fundamental parameters and analytical performance of a microwave-induced plasma optical emission spectrometry, four commercial nebulizers, Concentric, Mira Mist, OneNeb series 1, and OneNeb series 2, were evaluated. Estimated fundamental plasma parameters, excitation temperature (T), and the number of electron density (ne) indicated that the Mira Mist nebulizer afforded a plasma with the highest T and ne, but the lowest solvent transport efficiency. OneNeb series 2 showed the lowest T and ne, nonetheless the highest solvent transport efficiency. The precision was estimated in the middle of nitric acid (1% v v-1), sulfuric acid (1% v v-1), easily ionizable elements (100 mg L-1 of Ba, K, and Na), ethanol (1% v v-1), and carbon content (1000 mg L-1). The OneNeb series 2 presented the lowest RSD and LOD values in all matrices, while the concentric presented the highest RSD. The accuracy was evaluated by certified reference materials and addition and recovery experiments performed in sugarcane spirit. Considering the sensitivity improvement, solvent transport efficiency and analytical precision the OneNeb series 2 achieved superior performance. 653 $aConcentric 653 $aCrossflow 653 $aEnhanced parallel path 653 $aOptical emission spectrometry 653 $aPneumatic nebulizer 700 1 $aHIGUERA, J. M. 700 1 $aBRAZ, C. E. M. 700 1 $aMACHADO, R. C. 700 1 $aNOGUEIRA, A. R. de A. 773 $tSpectrochimica Acta Part B$gv. 168, p. 1614-1620, 105867, jun. 2020.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 1 | |
1. |  | LESSARD, C.; SIQUEIRA, L. G. B.; D'AMOURS, O.; SULLIVAN, R.; LECLERC, P.; PALMER, C. Infertility in a beef bull due to a failure in the capacitation process. Theriogenology, v. 76, n. 5, p. 891-899, 2011.Tipo: Artigo em Periódico Indexado | Circulação/Nível: A - 1 |
Biblioteca(s): Embrapa Gado de Leite. |
|    |
Registros recuperados : 1 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|