MYHRE, B. E.; SHIH, S. F.; SMAJSTRLA, A. G.; ZAZUETA, F. S. |
Título: |
Calibration of an infrared thermometer. |
Ano de publicação: |
1988 |
Fonte/Imprenta: |
Proceedings, v.47, p.99-102, 1988. |
Idioma: |
Inglês |
Conteúdo: |
The purpose of this study was to develp a procedure for the calibration of an infrared thermometer used for measurement of soil and plant-canopy temperatures. Three infrared thermometers were calibrated for surface-temperature measurements using an ice and a heated water bath. The infrared thermometers were also checked for linearilty of surface temperature measurements. The surface minus air-temperature readins were calibrated using and aluminum-foil-lined cardboard box. The effects of shadows on surface minu sair temperature measurements were also studied. The results for calibrating surface and surface-minus-air temperatures proved satisfactory. Also, the linearity of the infrared thermometers was determined to be within the mafacture's claimed limits. |
Palavras-Chave: |
Calibracao; Canopy temperature; Infrared thermometer. |
Thesagro: |
Temperatura. |
Thesaurus Nal: |
calibration. |
Categoria do assunto: |
-- |
Marc: |
LEADER 01309naa a2200217 a 4500 001 1073264 005 1993-03-25 008 1988 bl --- 0-- u #d 100 1 $aMYHRE, B. E. 245 $aCalibration of an infrared thermometer. 260 $c1988 520 $aThe purpose of this study was to develp a procedure for the calibration of an infrared thermometer used for measurement of soil and plant-canopy temperatures. Three infrared thermometers were calibrated for surface-temperature measurements using an ice and a heated water bath. The infrared thermometers were also checked for linearilty of surface temperature measurements. The surface minus air-temperature readins were calibrated using and aluminum-foil-lined cardboard box. The effects of shadows on surface minu sair temperature measurements were also studied. The results for calibrating surface and surface-minus-air temperatures proved satisfactory. Also, the linearity of the infrared thermometers was determined to be within the mafacture's claimed limits. 650 $acalibration 650 $aTemperatura 653 $aCalibracao 653 $aCanopy temperature 653 $aInfrared thermometer 700 1 $aSHIH, S. F. 700 1 $aSMAJSTRLA, A. G. 700 1 $aZAZUETA, F. S. 773 $tProceedings$gv.47, p.99-102, 1988.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Meio Norte / UEP-Parnaíba (CPAMN-UEPP) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 3 | |
Registros recuperados : 3 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|