|
|
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
10/11/2010 |
Data da última atualização: |
19/07/2011 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
GUERRA, M. B. B.; NOGUEIRA, A. R. de A.; SILVA, P. H. T.; PEREIRA FILHO, E. R. |
Afiliação: |
MARCELO BRAGA BUENO GUERRA, UFSCar/SÃO CARLOS, SP.; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; PATRICIA HELENA TONIOLO SILVA, UFSCar/SÃO CARLOS, SP.; EDENIR RODRIGUES PEREIRA FILHO, UFSCar/SÃO CARLOS, SP. |
Título: |
Acid digestion for cadmium determination in mineral salt mixing for animal nutrition by thermospra y flame furnace Atomic absorption spectrometry. |
Ano de publicação: |
2010 |
Fonte/Imprenta: |
In: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 11., 2010, Mar del Prata: Horiba, 2010. |
Páginas: |
p. 336 |
Idioma: |
Português |
Conteúdo: |
Cadmium was determined in a sample of mineral salt mixing to milk cattle that has been preparing to be a reference material. A volume of 3 mL of HNO3 3.0 mol L-1 plus 2.0 of H202 30% (W w-1) was added to 250 mg of sample in a cavity microwave oven. After digestion performance the volume was adjusted to 10 mL with water, centrifuged and the supernatant determined by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The system consist of a peristaltic pump, a lab-made commutator injector, and the thermospray flame furnace unit, which includes the ceramic capillary (0.5 mm 10,2.0 mm ED and 100 mm of length) and the Ni tube (10 cm) which is located on the AAS burner. For reaching a higher temperature inside the tube, six holes of 2 mm diameter were drilled in the bottom of the tube. Another orifice was drilled at 90' to the bottom holes for inserting the thermospray capillary. The capillary tip is about 1 mm inside the tube furnace. The manifold was assembled with 0.5 mm i.d. PTFE tubing, sample volume of 1 00 uL, 0.5 mL min-1 of flow rate, and 0.5 % (w v-1) EDTA plus 0.1 % (v v-1) Triton X 100 as carrier stream. Limits of detection (LOD) and quantification (LOQ) 'obtained were 0.31~g L-1 and 1.02~gL-1, respectively. The obtained results were 402 +- 35ug L-1. The accuracy was checked by performing GFAAS (465 +-95ug L-1) and the results proved to be similar by using t test. The high rsd in the GFAAS was probably due the high chloride sample amount. |
Palavras-Chave: |
Acid digestion; Atomic absorption; Spectrometry. |
Thesaurus Nal: |
animal nutrition. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/37803/1/PROCI-2010.00194.pdf
|
Marc: |
LEADER 02176nam a2200205 a 4500 001 1866622 005 2011-07-19 008 2010 bl uuuu u00u1 u #d 100 1 $aGUERRA, M. B. B. 245 $aAcid digestion for cadmium determination in mineral salt mixing for animal nutrition by thermospra y flame furnace Atomic absorption spectrometry. 260 $aIn: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 11., 2010, Mar del Prata: Horiba$c2010 300 $ap. 336 520 $aCadmium was determined in a sample of mineral salt mixing to milk cattle that has been preparing to be a reference material. A volume of 3 mL of HNO3 3.0 mol L-1 plus 2.0 of H202 30% (W w-1) was added to 250 mg of sample in a cavity microwave oven. After digestion performance the volume was adjusted to 10 mL with water, centrifuged and the supernatant determined by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The system consist of a peristaltic pump, a lab-made commutator injector, and the thermospray flame furnace unit, which includes the ceramic capillary (0.5 mm 10,2.0 mm ED and 100 mm of length) and the Ni tube (10 cm) which is located on the AAS burner. For reaching a higher temperature inside the tube, six holes of 2 mm diameter were drilled in the bottom of the tube. Another orifice was drilled at 90' to the bottom holes for inserting the thermospray capillary. The capillary tip is about 1 mm inside the tube furnace. The manifold was assembled with 0.5 mm i.d. PTFE tubing, sample volume of 1 00 uL, 0.5 mL min-1 of flow rate, and 0.5 % (w v-1) EDTA plus 0.1 % (v v-1) Triton X 100 as carrier stream. Limits of detection (LOD) and quantification (LOQ) 'obtained were 0.31~g L-1 and 1.02~gL-1, respectively. The obtained results were 402 +- 35ug L-1. The accuracy was checked by performing GFAAS (465 +-95ug L-1) and the results proved to be similar by using t test. The high rsd in the GFAAS was probably due the high chloride sample amount. 650 $aanimal nutrition 653 $aAcid digestion 653 $aAtomic absorption 653 $aSpectrometry 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aSILVA, P. H. T. 700 1 $aPEREIRA FILHO, E. R.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 34 | |
4. | | SILVA, A. B. S. da; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Direct determination of TiO2 as Ti used as digestibility marker in bovine faeces by Laser-Induced Breakdown Spectroscopy (LIBS). In: COLLOQUIUM SPECTROSCOPICUM INTERNATIONALE, 40., EURO-MEDITERRANEAN SYMPOSIUM ON LIBS, 9., 2017, Pisa, Italy. Proceedings... Pisa, Italy: IUPAC, 2017. p. 52.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
12. | | COUTINHO, H. L. C.; LIGO, M. A. V.; . NOVELLI, A. F.; BETTANIN, V. C.; PEREIRA FILHO, E. R. Monitoramento da população de microrganismos amonificadores e nitrificadores e de taxas de amonificação e nitrificação em solos sob cultivo de cana-de-açúcar na região de Ribeirão Preto, SP. In: CONGRESSO LATINO-AMERICANO DE CIENCIA DO SOLO, 13., 1996, Aguas de Lindoia. Resumos. Piracicaba: ESALQ / SBCS, 1996. CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Meio Ambiente. |
| |
14. | | GONZALES, M. H.; OLIVEIRA, R. V.; PEREIRA FILHO, E. R.; NÓBREGA, J. A; NOGUEIRA, A. R. de A. Quantificação de NBA's provenientes da digestão ácida de materiais biológicos assistida por radiação micro-ondas. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 15.; CONGRESSO IBEROAMERICANO DE QUÍMICA ANALÍTICA, 3., 2009, Salvador, BA. Anais... Salvador: SBQ: UFBA, 2009.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
16. | | DIB, S. R.; TULLIO, R. R.; NASSU, R. T.; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Determinação de metais por técnicas espectroanalíticas em amostras de carne e sangue de bovinos submetidos à dieta com adição de erva-mate (Ilex paraguariensis, St. Hilaire). In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 18., 2016, Florianópolis. Anais... Florianópolis: SBQ, 2016.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
20. | | CARAPELLI, R.; GROMBONI, C. F.; GOMES, M. S.; MIRANDA, K. A.; PEREIRA-FILHO, E. R.; NOGUEIRA, A. R. de A. Utilização de ferramentas quimiométricas e ICP OES para determinação de constituintes inorgânicos em alimentos estimulantes. In: ENCONTRO NACIONAL SOBRE CONTAMINANTES INORGÂNICOS 11.; SIMPÓSIO SOBRE ESSENCIALIDADE DE ELEMENTOS NA NUTRIÇÃO HUMANA, 6., 2008, Campinas. Anais... Campinas: Unicamp: GAGI: IQ, 2008. 185-187Tipo: Artigo em Anais de Congresso / Nota Técnica |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 34 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|