|
|
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
06/07/2021 |
Data da última atualização: |
28/09/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
MACHADO, R. C.; SILVA, A. B. S. da; ANDRADE, D. F. de; PINHEIRO, F. C.; WILLIAMS, C. B.; DONATI, G. L.; NOGUEIRA, A. R. de A.; PEREIRA FILHO, E. R. |
Afiliação: |
RAQUEL CARDOSO MACHADO, UFSCAR; ANA BEATRIZ SANTOS DA SILVA, UFSCAR; DANIEL FERNANDES DE ANDRADE, UFSCAR; FERNANDA COSTA PINHEIRO, UFSCAR; CHARLES B. WILLIAMS, Davidson College; GEORGE LUIS DONATI, Wake Forest University; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; EDENIR RODRIGUES PEREIRA FILHO, UFSCAR. |
Título: |
Alternative approaches applied to inductively coupled plasma techniques: multi-flow and two-flow calibration. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Journal of the Brazilian Chemical Society, v.32, n.4, 2021. |
Páginas: |
p.842-851. |
ISSN: |
0103-5053 |
DOI: |
https://dx.doi.org/10.21577/0103-5053.20200235 |
Idioma: |
Inglês |
Conteúdo: |
Multi-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) to analyze different and complexmatrix samples. Al, As, Cd, Cr, Cu, Mn, Pb, and Zn were determined by ICP OES, while As, Cd, Co, Cu, Hg, Mo, Mn, Ni, Se, Sb, Pb, and V were determined by ICP-MS. MFC results were compared with those obtained using external standard calibration (EC) for both techniques and in all cases, MFC showed equal or superior accuracy (recoveries between 80-120%) compared to EC, and lower relative standard deviation (RSDs < 10%). Several tests were also performed using only two nebulization gas flows to build linear models for calibration (called two-flow calibration, TFC) and the accurate results (recoveries ranged from 80 to 110% for ICP OES and from 81 to 102% for ICP-MS) suggests that this strategy can be also applied, resulting in a method with high sample throughput. |
Palavras-Chave: |
Calibration strategy; ICP OES; ICP-MS; Matrix effects; Nebulization gas. |
Categoria do assunto: |
W Química e Física |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/224314/1/Alternative-Approaches-Applied.pdf
|
Marc: |
LEADER 02162naa a2200301 a 4500 001 2132812 005 2021-09-28 008 2021 bl uuuu u00u1 u #d 022 $a0103-5053 024 7 $ahttps://dx.doi.org/10.21577/0103-5053.20200235$2DOI 100 1 $aMACHADO, R. C. 245 $aAlternative approaches applied to inductively coupled plasma techniques$bmulti-flow and two-flow calibration.$h[electronic resource] 260 $c2021 300 $ap.842-851. 520 $aMulti-flow calibration (MFC) is based on monitoring the analytical signal from a single calibration standard solution at several different nebulization gas flow rates (Q), which normalizes plasma conditions and minimizes matrix effects. In the present study, MFC was evaluated, for the first time, applied to inductively coupled plasma optical emission spectrometry (ICP OES) and inductively coupled plasma mass spectrometry (ICP-MS) to analyze different and complexmatrix samples. Al, As, Cd, Cr, Cu, Mn, Pb, and Zn were determined by ICP OES, while As, Cd, Co, Cu, Hg, Mo, Mn, Ni, Se, Sb, Pb, and V were determined by ICP-MS. MFC results were compared with those obtained using external standard calibration (EC) for both techniques and in all cases, MFC showed equal or superior accuracy (recoveries between 80-120%) compared to EC, and lower relative standard deviation (RSDs < 10%). Several tests were also performed using only two nebulization gas flows to build linear models for calibration (called two-flow calibration, TFC) and the accurate results (recoveries ranged from 80 to 110% for ICP OES and from 81 to 102% for ICP-MS) suggests that this strategy can be also applied, resulting in a method with high sample throughput. 653 $aCalibration strategy 653 $aICP OES 653 $aICP-MS 653 $aMatrix effects 653 $aNebulization gas 700 1 $aSILVA, A. B. S. da 700 1 $aANDRADE, D. F. de 700 1 $aPINHEIRO, F. C. 700 1 $aWILLIAMS, C. B. 700 1 $aDONATI, G. L. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aPEREIRA FILHO, E. R. 773 $tJournal of the Brazilian Chemical Society$gv.32, n.4, 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 34 | |
3. | | SILVA, A. B. S. da; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Direct determination of TiO2 as Ti used as digestibility marker in bovine faeces by Laser-Induced Breakdown Spectroscopy (LIBS). In: COLLOQUIUM SPECTROSCOPICUM INTERNATIONALE, 40., EURO-MEDITERRANEAN SYMPOSIUM ON LIBS, 9., 2017, Pisa, Italy. Proceedings... Pisa, Italy: IUPAC, 2017. p. 52.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
13. | | DIB, S. R.; TULLIO, R. R.; NASSU, R. T.; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Determinação de metais por técnicas espectroanalíticas em amostras de carne e sangue de bovinos submetidos à dieta com adição de erva-mate (Ilex paraguariensis, St. Hilaire). In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 18., 2016, Florianópolis. Anais... Florianópolis: SBQ, 2016.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
16. | | COUTINHO, H. L. C.; LIGO, M. A. V.; . NOVELLI, A. F.; BETTANIN, V. C.; PEREIRA FILHO, E. R. Monitoramento da população de microrganismos amonificadores e nitrificadores e de taxas de amonificação e nitrificação em solos sob cultivo de cana-de-açúcar na região de Ribeirão Preto, SP. In: CONGRESSO LATINO-AMERICANO DE CIENCIA DO SOLO, 13., 1996, Aguas de Lindoia. Resumos. Piracicaba: ESALQ / SBCS, 1996. CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Meio Ambiente. |
| |
17. | | GONZALEZ, M. H.; OLIVEIRA, R. V.; PEREIRA FILHO, E. R.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Otimização da separação de isômeros de ácidos nitrobenzóicos resultantes da digestão ácida de materiais biológicos. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 14., 2007, João Pessoa, PB. Anais... João Pessoa: SBQA, 2007. 1 CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
18. | | GONZALES, M. H.; OLIVEIRA, R. V.; PEREIRA FILHO, E. R.; NÓBREGA, J. A; NOGUEIRA, A. R. de A. Quantificação de NBA?s provenientes da digestão ácida de materiais biológicos assistida por radiação micro-ondas. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 15.; CONGRESSO IBEROAMERICANO DE QUÍMICA ANALÍTICA, 3., 2009, Salvador, BA. Anais... Salvador: SBQ: UFBA, 2009.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
20. | | CARAPELLI, R.; GUERRA, M. B. B.; MIRANDA, K. dos A. de; PEREIRA FILHO, E. R.; NOGUEIRA, A. R. de A. Potentialities of hydride generation atomic absorption spectrometry (HGAAS) in the fast sequential determination of AS, BI and SB. In: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 11., 2010, Mar del Prata: Horiba, 2010. p. 169Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 34 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|