|
|
Registro Completo |
Biblioteca(s): |
Embrapa Semiárido. |
Data corrente: |
04/10/2013 |
Data da última atualização: |
23/01/2024 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
SILVA, C. S. B. da; PAZ, H. H. R.; COELHO, R. de S.; COSTA, V. A.; PARANHOS, B. A. J.; OLIVEIRA, J. E. de M. |
Afiliação: |
CHERRE S. B. DA SILVA; HUANNA H. R. PAZ; ROSAMARA DE S. COELHO; VALMIR A. COSTA; BEATRIZ AGUIAR GIORDANO PARANHOS, CPATSA; JOSE EUDES DE MORAIS OLIVEIRA, CPATSA. |
Título: |
Honeydew of Planococcus citri (Pseudococcidae) increases longevity and locomotory activity of its parasitoid, Coccidoxenoides perminutus (Encyrtidae). |
Ano de publicação: |
2013 |
Fonte/Imprenta: |
In: SIMPÓSIO DE CONTROLE BIOLÓGICO, 13., 2013, Bonito. Faça bonito: use controle biológico: anais. Brasília, DF: Embrapa, 2013. |
Descrição Física: |
1 CD-ROM. |
Idioma: |
Inglês |
Conteúdo: |
We performed a sequence of assays in order to determine the effect of the honeydew released by Planococcus citri on the biology of its parasitoid, Coccidoxenoides perminutus. |
Palavras-Chave: |
Busca de hospedeiro; Comportamento parasitóide; Estimulante locomotor; SICONBIOL 2013. |
Thesagro: |
Ceratitis Capitata; Controle biológico; Entomologia; Inseto; Mosca das Frutas; Praga. |
Thesaurus Nal: |
Biological control; Entomology; Fruit flies. |
Categoria do assunto: |
O Insetos e Entomologia |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/90471/1/Cherre70.pdf
|
Marc: |
LEADER 01269nam a2200337 a 4500 001 1967819 005 2024-01-23 008 2013 bl uuuu u00u1 u #d 100 1 $aSILVA, C. S. B. da 245 $aHoneydew of Planococcus citri (Pseudococcidae) increases longevity and locomotory activity of its parasitoid, Coccidoxenoides perminutus (Encyrtidae). 260 $aIn: SIMPÓSIO DE CONTROLE BIOLÓGICO, 13., 2013, Bonito. Faça bonito: use controle biológico: anais. Brasília, DF: Embrapa$c2013 300 $c1 CD-ROM. 520 $aWe performed a sequence of assays in order to determine the effect of the honeydew released by Planococcus citri on the biology of its parasitoid, Coccidoxenoides perminutus. 650 $aBiological control 650 $aEntomology 650 $aFruit flies 650 $aCeratitis Capitata 650 $aControle biológico 650 $aEntomologia 650 $aInseto 650 $aMosca das Frutas 650 $aPraga 653 $aBusca de hospedeiro 653 $aComportamento parasitóide 653 $aEstimulante locomotor 653 $aSICONBIOL 2013 700 1 $aPAZ, H. H. R. 700 1 $aCOELHO, R. de S. 700 1 $aCOSTA, V. A. 700 1 $aPARANHOS, B. A. J. 700 1 $aOLIVEIRA, J. E. de M.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Semiárido (CPATSA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registro Completo
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
13/12/2021 |
Data da última atualização: |
13/12/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 2 |
Autoria: |
PALHARES, J. C. P.; MORELLI, M.; NOVELLI, T. I.; MÉO FILHO, P. DE; HISATUGU, M. T. |
Afiliação: |
JULIO CESAR PASCALE PALHARES, CPPSE; MARCELA MORELLI, USP; TÁISLA INARA NOVELLI, USP; PAULO DE MÉO FILHO, Rothamsted Research; MATHEUS TOSHIO HISATUGU, USP. |
Título: |
Comparison of two water measurement systems for feedlot beef cattle. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Ambiente & Água, v.16, n.4, 2021. |
Páginas: |
7 p. |
ISSN: |
1980-993X |
DOI: |
https://doi.org/10.4136/ambi-agua.2729 |
Idioma: |
Inglês |
Conteúdo: |
The objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages. MenosThe objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with ... Mostrar Tudo |
Palavras-Chave: |
Bebedouro eletrônico; Electronic drinkers; Pecuária de precisão; Precision livestock farming; Water meter. |
Thesagro: |
Hidrômetro. |
Categoria do assunto: |
X Pesquisa, Tecnologia e Engenharia |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/229006/1/ComparisonTwoWater.pdf
|
Marc: |
LEADER 02336naa a2200277 a 4500 001 2137650 005 2021-12-13 008 2021 bl uuuu u00u1 u #d 022 $a1980-993X 024 7 $ahttps://doi.org/10.4136/ambi-agua.2729$2DOI 100 1 $aPALHARES, J. C. P. 245 $aComparison of two water measurement systems for feedlot beef cattle.$h[electronic resource] 260 $c2021 300 $a7 p. 520 $aThe objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages. 650 $aHidrômetro 653 $aBebedouro eletrônico 653 $aElectronic drinkers 653 $aPecuária de precisão 653 $aPrecision livestock farming 653 $aWater meter 700 1 $aMORELLI, M. 700 1 $aNOVELLI, T. I. 700 1 $aMÉO FILHO, P. DE 700 1 $aHISATUGU, M. T. 773 $tAmbiente & Água$gv.16, n.4, 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|