|
|
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
13/12/2021 |
Data da última atualização: |
13/12/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
PALHARES, J. C. P.; MORELLI, M.; NOVELLI, T. I.; MÉO FILHO, P. DE; HISATUGU, M. T. |
Afiliação: |
JULIO CESAR PASCALE PALHARES, CPPSE; MARCELA MORELLI, USP; TÁISLA INARA NOVELLI, USP; PAULO DE MÉO FILHO, Rothamsted Research; MATHEUS TOSHIO HISATUGU, USP. |
Título: |
Comparison of two water measurement systems for feedlot beef cattle. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Ambiente & Água, v.16, n.4, 2021. |
Páginas: |
7 p. |
ISSN: |
1980-993X |
DOI: |
https://doi.org/10.4136/ambi-agua.2729 |
Idioma: |
Inglês |
Conteúdo: |
The objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages. MenosThe objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with ... Mostrar Tudo |
Palavras-Chave: |
Bebedouro eletrônico; Electronic drinkers; Pecuária de precisão; Precision livestock farming; Water meter. |
Thesagro: |
Hidrômetro. |
Categoria do assunto: |
X Pesquisa, Tecnologia e Engenharia |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/229006/1/ComparisonTwoWater.pdf
|
Marc: |
LEADER 02336naa a2200277 a 4500 001 2137650 005 2021-12-13 008 2021 bl uuuu u00u1 u #d 022 $a1980-993X 024 7 $ahttps://doi.org/10.4136/ambi-agua.2729$2DOI 100 1 $aPALHARES, J. C. P. 245 $aComparison of two water measurement systems for feedlot beef cattle.$h[electronic resource] 260 $c2021 300 $a7 p. 520 $aThe objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages. 650 $aHidrômetro 653 $aBebedouro eletrônico 653 $aElectronic drinkers 653 $aPecuária de precisão 653 $aPrecision livestock farming 653 $aWater meter 700 1 $aMORELLI, M. 700 1 $aNOVELLI, T. I. 700 1 $aMÉO FILHO, P. DE 700 1 $aHISATUGU, M. T. 773 $tAmbiente & Água$gv.16, n.4, 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registro Completo
Biblioteca(s): |
Embrapa Agroindústria de Alimentos. |
Data corrente: |
26/01/2011 |
Data da última atualização: |
22/01/2013 |
Tipo da produção científica: |
Documentos |
Autoria: |
PENHA, E. das M.; SOUZA, A. M. de; SANTIAGO, M. C. P. de A.; CENDON, B. R.; SILVA, R. R. de B.; ARAÚJO, A. M. |
Afiliação: |
EDMAR DAS MERCES PENHA, CTAA; ANDRESSA MOREIRA DE SOUZA, CTAA; MANUELA CRISTINA P DE A SANTIAGO, CTAA; BERNARDO RIBEIRO CENDON, CTAA; ROSIANE RIBEIRO DE BARROS SILVA, CEFET-RJ; ALINE MOREIRA DE ARAÚJO, CEFET QUÍMICA. |
Título: |
Manual de operação e manutenção da estação de tratamento de efluentes da Embrapa Agroindústria de Alimentos. |
Ano de publicação: |
2010 |
Fonte/Imprenta: |
Rio de Janeiro: Embrapa Agroindústria de Alimentos, 2010. |
Série: |
(Embrapa Agroindústria de Alimentos. Documentos, 106). |
Idioma: |
Português |
Palavras-Chave: |
Embrapa Agroindústria de Alimentos. |
Thesagro: |
Águas residuais; Tratamento de esgoto. |
Thesaurus NAL: |
Sewage treatment; Wastewater treatment. |
Categoria do assunto: |
P Recursos Naturais, Ciências Ambientais e da Terra |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/75005/1/pub-202.pdf
|
Marc: |
LEADER 00794nam a2200229 a 4500 001 1874586 005 2013-01-22 008 2010 bl uuuu u0uu1 u #d 100 1 $aPENHA, E. das M. 245 $aManual de operação e manutenção da estação de tratamento de efluentes da Embrapa Agroindústria de Alimentos. 260 $aRio de Janeiro: Embrapa Agroindústria de Alimentos$c2010 490 $a(Embrapa Agroindústria de Alimentos. Documentos, 106). 650 $aSewage treatment 650 $aWastewater treatment 650 $aÁguas residuais 650 $aTratamento de esgoto 653 $aEmbrapa Agroindústria de Alimentos 700 1 $aSOUZA, A. M. de 700 1 $aSANTIAGO, M. C. P. de A. 700 1 $aCENDON, B. R. 700 1 $aSILVA, R. R. de B. 700 1 $aARAÚJO, A. M.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Agroindústria de Alimentos (CTAA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|