VIRGILIO, A.; SILVA, A. B. S.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A.; DONATI, G. L. |
Afiliação: |
Alex Virgilio, USP; Ana Beatriz S. Silva, UFSCAR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; Joaquim A. Nóbrega, UFSCAR; George L. Donati, Wake Forest University. |
Título: |
Calculating limits of detection and defining working ranges for multi-signal calibration methods. |
Ano de publicação: |
2020 |
Fonte/Imprenta: |
Journal of Analytical Atomic Spectrometry, v. 35, p. 1614-1620, 2020 |
DOI: |
10.1039/d0ja00212g |
Idioma: |
Inglês |
Conteúdo: |
Multi-signal calibration methods, such as multi-energy calibration (MEC) and multi-isotope calibration (MICal), have increasingly been used to improve the efficiency of spectrochemical instrumental analyses. As MEC and MICal are adopted by an increasing number of laboratories, questions on their working ranges, the most appropriate calibration standard concentration (Cstd) to be used, and the best approach to calculate limits of detection (LOD) and quantification (LOQ) have been raised. In this study, we evaluate the effects of working with different combinations of Cstd and analyte concentration in the sample (Csam) on the accuracy of MEC and MICal. Chromium, Cu and Mo are used as models for MEC determinations by microwave-induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma OES (ICP OES), and MICal determinations by ICP mass spectrometry (ICP-MS), respectively. We use the error propagation approach to determine LODs and LOQs, evaluate the effect of employing different values of Cstd in these calculations, and compare the results with those from external standard calibration (EC) using the IUPAC approach. Finally, we apply MEC and MICal to analyze certified reference materials and compare the results with those from the traditional standard additions (SA) method. Although presenting usually higher LODs and LOQs compared to EC, MEC and MICal generally provide trueness similar to, and sometimes better than, SA. LOD and LOQ calculations based on the error propagation approach provide robust results, and trueness and precision depend on the calibration slope and the analyte level in the sample. The best results for MEC and MICal are found when working within the 0.1 < calibration slope < 0.9 range. A simple pre-analysis test comparing the analytical signal recorded for the sample (Isam) and a calibration standard (Istd) may ensure such conditions if 0.11 MenosMulti-signal calibration methods, such as multi-energy calibration (MEC) and multi-isotope calibration (MICal), have increasingly been used to improve the efficiency of spectrochemical instrumental analyses. As MEC and MICal are adopted by an increasing number of laboratories, questions on their working ranges, the most appropriate calibration standard concentration (Cstd) to be used, and the best approach to calculate limits of detection (LOD) and quantification (LOQ) have been raised. In this study, we evaluate the effects of working with different combinations of Cstd and analyte concentration in the sample (Csam) on the accuracy of MEC and MICal. Chromium, Cu and Mo are used as models for MEC determinations by microwave-induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma OES (ICP OES), and MICal determinations by ICP mass spectrometry (ICP-MS), respectively. We use the error propagation approach to determine LODs and LOQs, evaluate the effect of employing different values of Cstd in these calculations, and compare the results with those from external standard calibration (EC) using the IUPAC approach. Finally, we apply MEC and MICal to analyze certified reference materials and compare the results with those from the traditional standard additions (SA) method. Although presenting usually higher LODs and LOQs compared to EC, MEC and MICal generally provide trueness similar to, and sometimes better than, SA. LOD and LOQ calculations based o... Mostrar Tudo |
Palavras-Chave: |
Analyte concentration in the sample; Calibration methods; Calibration standard concentration; Limits of detection; Limits of quantification; Multi energy calibration; Multi isotope calibration. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02991naa a2200265 a 4500 001 2127525 005 2020-12-03 008 2020 bl uuuu u00u1 u #d 024 7 $a10.1039/d0ja00212g$2DOI 100 1 $aVIRGILIO, A. 245 $aCalculating limits of detection and defining working ranges for multi-signal calibration methods.$h[electronic resource] 260 $c2020 520 $aMulti-signal calibration methods, such as multi-energy calibration (MEC) and multi-isotope calibration (MICal), have increasingly been used to improve the efficiency of spectrochemical instrumental analyses. As MEC and MICal are adopted by an increasing number of laboratories, questions on their working ranges, the most appropriate calibration standard concentration (Cstd) to be used, and the best approach to calculate limits of detection (LOD) and quantification (LOQ) have been raised. In this study, we evaluate the effects of working with different combinations of Cstd and analyte concentration in the sample (Csam) on the accuracy of MEC and MICal. Chromium, Cu and Mo are used as models for MEC determinations by microwave-induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma OES (ICP OES), and MICal determinations by ICP mass spectrometry (ICP-MS), respectively. We use the error propagation approach to determine LODs and LOQs, evaluate the effect of employing different values of Cstd in these calculations, and compare the results with those from external standard calibration (EC) using the IUPAC approach. Finally, we apply MEC and MICal to analyze certified reference materials and compare the results with those from the traditional standard additions (SA) method. Although presenting usually higher LODs and LOQs compared to EC, MEC and MICal generally provide trueness similar to, and sometimes better than, SA. LOD and LOQ calculations based on the error propagation approach provide robust results, and trueness and precision depend on the calibration slope and the analyte level in the sample. The best results for MEC and MICal are found when working within the 0.1 < calibration slope < 0.9 range. A simple pre-analysis test comparing the analytical signal recorded for the sample (Isam) and a calibration standard (Istd) may ensure such conditions if 0.11 <Isam/Istd < 9.00. MEC and MICal are simple and efficient alternatives to EC and SA. They are particularly effective for minimizing matrix effects and analyzing complex-matrix samples. 653 $aAnalyte concentration in the sample 653 $aCalibration methods 653 $aCalibration standard concentration 653 $aLimits of detection 653 $aLimits of quantification 653 $aMulti energy calibration 653 $aMulti isotope calibration 700 1 $aSILVA, A. B. S. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aNÓBREGA, J. A. 700 1 $aDONATI, G. L. 773 $tJournal of Analytical Atomic Spectrometry$gv. 35, p. 1614-1620, 2020
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 15 | |
4. | | GROMBONI, C. F.; MATOS, W. O.; DONATI, G. L.; NEVES, E. A.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Avaliação de alternativas para o tratamento de resíduo contendo cromo hexavalente. In: REUNIÃO ANUAL DA SOCIEDADE BRASILEIRA DE QUÍMICA, 29., 2006, Águas de Lindóia, SP. Anais... Águas de Lindóia: SBQ, 2006. 1 CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
5. | | GROMBONI, C. F.; MATOS, W. O.; DONATI, G. L.; NEVES, E. A.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Avaliação de alternativas para o tratamento de resíduos contendo cromo Hexavalente. In: SIMPÓSIO DE INICIAÇÃO CIENTÍFICA DA EMBRAPA PECUÁRIA SUDESTE, 2006, São Carlos, SP. Anais... São Carlos: Embrapa Pecuária Sudeste, 2006. (Documentos / Embrapa Pecuária Sudeste; 62).Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
8. | | ROSINI, F.; DONATI, G. L.; NASCENTES, C. C.; ARRUDA, M. A. Z.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS_FF_AAS): comportamento dos elementos selênio e cobalto. In: CONGRESSO DE PÓS GRADUAÇÃO DA UNIVERSIDADE FEDERAL DE SÃO CARLOS, 3., 2005, São Carlos. Anais... São Carlos: UFSCar, 2005. v. 1. p. 1561-1562.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
9. | | DONATI, G. L.; NASCENTES, C. C.; NOGUEIRA, A. R. de A.; ARRUDA, M. A. Z.; NÓBREGA, J. A. Determinação de cobalto em amostras biológicas por espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS). In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 13.; CONGRESSO ÍBERO - AMERICANO DE QUÍMICA ANALÍTICA, 2005, Niterói, RJ. Anais... Niterói: BENQ, 2005. 1 CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
10. | | AMARAL, C. D. B.; PESSOA, A. G. G.; SANTOS, M. C.; DONATI, G. L.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Avaliação de diferentes preparos de amostra para especiação de arsênio em tecido vegetal por HPLC-ICP-MS com o emprego de padronização interna com espécie poliatômica. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 16., 2011, Campos de Jordão. Anais... Campos de Jordão: SBQ, 2011.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
13. | | MARCANO DE HIGUERA, J.; SILVA, A. B. S. da; HENRIQUE, W.; ESTEVES, S. N.; BARIONI JUNIOR, W.; DONATI, G. L.; NOGUEIRA, A. R. de A. Effect of genetic crossing and nutritional management on the mineral composition of carcass, blood, leather, and viscera of sheep. Biological Trace Element Research, jan. 2021. p.4133-4144.Tipo: Artigo em Periódico Indexado | Circulação/Nível: B - 1 |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
14. | | PESSOA, A. G. G.; AMARAL, C. D. do; SANTOS, M. C. dos; DONATI, G. L.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Emprego de extração assistida por radiação micro-ondas e padrão de interferência para especiação de arsênio por HPLC-ICP-MS. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 16., 2011, Campos de Jordão. Anais... Campos de Jordão: SBQ, 2011.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
15. | | MACHADO, R. C.; SILVA, A. B. S. da; ANDRADE, D. F. de; PINHEIRO, F. C.; WILLIAMS, C. B.; DONATI, G. L.; NOGUEIRA, A. R. de A.; PEREIRA FILHO, E. R. Alternative approaches applied to inductively coupled plasma techniques: multi-flow and two-flow calibration. Journal of the Brazilian Chemical Society, v.32, n.4, 2021. p.842-851.Tipo: Artigo em Periódico Indexado | Circulação/Nível: A - 2 |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 15 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|