|
|
Registro Completo |
Biblioteca(s): |
Embrapa Soja. |
Data corrente: |
24/03/2021 |
Data da última atualização: |
03/05/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
ABATI, J.; BRZEZINSKI, C. R.; ZUCARELI, C.; WERNER, F.; HENNING, A. A.; HENNING, F. A. |
Afiliação: |
JULIA ABATI, Universidade Estadual de Maringá, UEM, Maringá, PR.; CRISTIAN RAFAEL BRZEZINSKI, Gdm Genetica Do Brasil S. A., Porto Nacional, TO; CLAUDEMIR ZUCARELI, Universidade Estadual de Londrina, UEL, Londrina, PR.; FLÁVIA WERNER, Universidade Estadual de Londrina, UEL, Londrina, PR.; ADEMIR ASSIS HENNING, CNPSO; FERNANDO AUGUSTO HENNING, CNPSO. |
Título: |
Physiological potential of soybean industrially treated with different spray volumes and dry powder. |
Ano de publicação: |
2020 |
Fonte/Imprenta: |
Australian Journal of Crop Science, v. 14, n. 5, p. 836-841, 2020. |
ISSN: |
1835-2707 |
DOI: |
10.21475/ajcs.20.14.05.p2412 |
Idioma: |
Inglês |
Conteúdo: |
The industrial treatment of seeds has favored the development of new technologies such as the use of dry powder. It has made application of spray volumes higher than those used in the conventional treatment. Therefore, this study aimed to assess the effect of industrial treatments at different spray volumes with and without application of dry powder on physiological quality of soybean seeds. A completely randomized experimental design was performed with four replications in a 5 x 2 factorial arrangement for cultivars BRS 359 RR and BRS 284. The factors were five spray volumes (0, 600, 1200, 1800 and 2400 mL. 100 kg-1) with and without the application of dry powder. The products used to obtain the volumes were fungicides (carbendazim + thiram); insecticides (imidacloprid + thiodicarb); nematicide (abamectin); micronutrients (cobalt, molybdenum and zinc); polymer (peridiam); biostimulant (kinetin + gibberellic acid + 4-indol-3-ylbutyric acid) and inoculant (Bradyrhizobium japonicum). The physiological quality of the seeds was determined by the following assessments: germination, first count of germination test, seedling emergence in sand, emergence speed index, and total length of the seedling shoot and root. The results showed that increased spray volume associated with the application of dry powder in seed treatment reduced the physiological quality of soybean seeds, and spray volumes up to 1200 mL 100 kg-1 in seed treatment without the application of dry powder do not impact the emergence and establishment of soybean seedlings. MenosThe industrial treatment of seeds has favored the development of new technologies such as the use of dry powder. It has made application of spray volumes higher than those used in the conventional treatment. Therefore, this study aimed to assess the effect of industrial treatments at different spray volumes with and without application of dry powder on physiological quality of soybean seeds. A completely randomized experimental design was performed with four replications in a 5 x 2 factorial arrangement for cultivars BRS 359 RR and BRS 284. The factors were five spray volumes (0, 600, 1200, 1800 and 2400 mL. 100 kg-1) with and without the application of dry powder. The products used to obtain the volumes were fungicides (carbendazim + thiram); insecticides (imidacloprid + thiodicarb); nematicide (abamectin); micronutrients (cobalt, molybdenum and zinc); polymer (peridiam); biostimulant (kinetin + gibberellic acid + 4-indol-3-ylbutyric acid) and inoculant (Bradyrhizobium japonicum). The physiological quality of the seeds was determined by the following assessments: germination, first count of germination test, seedling emergence in sand, emergence speed index, and total length of the seedling shoot and root. The results showed that increased spray volume associated with the application of dry powder in seed treatment reduced the physiological quality of soybean seeds, and spray volumes up to 1200 mL 100 kg-1 in seed treatment without the application of dry powder do not impac... Mostrar Tudo |
Palavras-Chave: |
Dry powder; Glycine max (L) Merrill. |
Thesagro: |
Aspecto Fisiológico; Fungicida; Germinação; Glycine Max; Inseticida; Pó Seco; Pulverização; Soja; Teste de Vigor. |
Thesaurus Nal: |
Fungicides; Germination; Insecticides; Physiological response; Soybeans; Spray volume; Vigor. |
Categoria do assunto: |
F Plantas e Produtos de Origem Vegetal |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/222095/1/abati-14-5-2020-836-841.pdf
|
Marc: |
LEADER 02712naa a2200421 a 4500 001 2130886 005 2021-05-03 008 2020 bl uuuu u00u1 u #d 022 $a1835-2707 024 7 $a10.21475/ajcs.20.14.05.p2412$2DOI 100 1 $aABATI, J. 245 $aPhysiological potential of soybean industrially treated with different spray volumes and dry powder.$h[electronic resource] 260 $c2020 520 $aThe industrial treatment of seeds has favored the development of new technologies such as the use of dry powder. It has made application of spray volumes higher than those used in the conventional treatment. Therefore, this study aimed to assess the effect of industrial treatments at different spray volumes with and without application of dry powder on physiological quality of soybean seeds. A completely randomized experimental design was performed with four replications in a 5 x 2 factorial arrangement for cultivars BRS 359 RR and BRS 284. The factors were five spray volumes (0, 600, 1200, 1800 and 2400 mL. 100 kg-1) with and without the application of dry powder. The products used to obtain the volumes were fungicides (carbendazim + thiram); insecticides (imidacloprid + thiodicarb); nematicide (abamectin); micronutrients (cobalt, molybdenum and zinc); polymer (peridiam); biostimulant (kinetin + gibberellic acid + 4-indol-3-ylbutyric acid) and inoculant (Bradyrhizobium japonicum). The physiological quality of the seeds was determined by the following assessments: germination, first count of germination test, seedling emergence in sand, emergence speed index, and total length of the seedling shoot and root. The results showed that increased spray volume associated with the application of dry powder in seed treatment reduced the physiological quality of soybean seeds, and spray volumes up to 1200 mL 100 kg-1 in seed treatment without the application of dry powder do not impact the emergence and establishment of soybean seedlings. 650 $aFungicides 650 $aGermination 650 $aInsecticides 650 $aPhysiological response 650 $aSoybeans 650 $aSpray volume 650 $aVigor 650 $aAspecto Fisiológico 650 $aFungicida 650 $aGerminação 650 $aGlycine Max 650 $aInseticida 650 $aPó Seco 650 $aPulverização 650 $aSoja 650 $aTeste de Vigor 653 $aDry powder 653 $aGlycine max (L) Merrill 700 1 $aBRZEZINSKI, C. R. 700 1 $aZUCARELI, C. 700 1 $aWERNER, F. 700 1 $aHENNING, A. A. 700 1 $aHENNING, F. A. 773 $tAustralian Journal of Crop Science$gv. 14, n. 5, p. 836-841, 2020.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Soja (CNPSO) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Instrumentação. Para informações adicionais entre em contato com cnpdia.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Instrumentação. |
Data corrente: |
22/12/1999 |
Data da última atualização: |
11/03/2010 |
Autoria: |
COLNAGO, L. A.; MARTIN-NETO, L.; NEVES, M. C. P. |
Afiliação: |
EMBRAPA-CNPDIA. |
Título: |
Instrumento para análise de hidrogênio e outros gases combustíveis. |
Ano de publicação: |
1990 |
Fonte/Imprenta: |
In: ENCONTRO REGIONAL DE QUIMICA, 9., dez. 1990, Sao Carlos, SP. Comunicacoes... São Carlos: Sociedade Brasileira de Quimica, 1990. |
Páginas: |
p.73. |
Idioma: |
Português |
Notas: |
Resumo. |
Conteúdo: |
Construiu-se um instrumento para analisar tracos de hidrogenio, baseado no detector de gas figaro. O equipamento consiste de dois sensores de gas figaro, um circuito linearizador e um circuito que permite a saida para um registrador. Foi tambem construido, como acessorio desse equipamento, um seletor automatico que permite monitorar automaticamente ate 12 amostras ou experimentos. Um dos sensores foi construido para analisar o hidrogenio diretamente no ar, pois o oxigenio, o gas carbonico, o nitrogenio e o vapor d'agua nao sao detectaveis. Ao outro sensor foi acoplada uma coluna de cromatografia de gas para separar o hidrogenio dos outros gases combustiveis, como o metano, etano, CO etc., bem como analisa-los. O analisador esta sendo usado nos projetos de fixacao biologica do nitrogenio, por bacteria do genero Rhizobium. Como ha uma correlacao inversa entre a fixacao de nitrogenio e a liberacao de hidrogenio, esta sendo usado nos processos de selecao de estirpes de bacteria mais eficientes na fixacao de nitrogenio. As principais vantagens desse equipamento sobre o cromatografo com detector de condutividade termica sao: a simplicidade de uso; a alta seletividade e sensibilidade ao hidrogenio; e muito mais sensivel do que os detectores de condutividade termica dos cromatografos de gas; nao detecta oxigenio, gas carbonico, nitrogenios e vapor d'agua, o que permite usar o proprio ar como gas de arraste, dispensando o uso de gas puro, entre outras. |
Palavras-Chave: |
Detector de gas figaro; gás carbônico; vapor d' água. |
Thesagro: |
Hidrogênio; Nitrogênio; Oxigênio. |
Categoria do assunto: |
-- |
Marc: |
LEADER 02188naa a2200241 a 4500 001 1026629 005 2010-03-11 008 1990 bl --- 0-- u #d 100 1 $aCOLNAGO, L. A. 245 $aInstrumento para análise de hidrogênio e outros gases combustíveis. 260 $c1990 300 $ap.73. 500 $aResumo. 520 $aConstruiu-se um instrumento para analisar tracos de hidrogenio, baseado no detector de gas figaro. O equipamento consiste de dois sensores de gas figaro, um circuito linearizador e um circuito que permite a saida para um registrador. Foi tambem construido, como acessorio desse equipamento, um seletor automatico que permite monitorar automaticamente ate 12 amostras ou experimentos. Um dos sensores foi construido para analisar o hidrogenio diretamente no ar, pois o oxigenio, o gas carbonico, o nitrogenio e o vapor d'agua nao sao detectaveis. Ao outro sensor foi acoplada uma coluna de cromatografia de gas para separar o hidrogenio dos outros gases combustiveis, como o metano, etano, CO etc., bem como analisa-los. O analisador esta sendo usado nos projetos de fixacao biologica do nitrogenio, por bacteria do genero Rhizobium. Como ha uma correlacao inversa entre a fixacao de nitrogenio e a liberacao de hidrogenio, esta sendo usado nos processos de selecao de estirpes de bacteria mais eficientes na fixacao de nitrogenio. As principais vantagens desse equipamento sobre o cromatografo com detector de condutividade termica sao: a simplicidade de uso; a alta seletividade e sensibilidade ao hidrogenio; e muito mais sensivel do que os detectores de condutividade termica dos cromatografos de gas; nao detecta oxigenio, gas carbonico, nitrogenios e vapor d'agua, o que permite usar o proprio ar como gas de arraste, dispensando o uso de gas puro, entre outras. 650 $aHidrogênio 650 $aNitrogênio 650 $aOxigênio 653 $aDetector de gas figaro 653 $agás carbônico 653 $avapor d' água 700 1 $aMARTIN-NETO, L. 700 1 $aNEVES, M. C. P. 773 $tIn: ENCONTRO REGIONAL DE QUIMICA, 9., dez. 1990, Sao Carlos, SP. Comunicacoes... São Carlos: Sociedade Brasileira de Quimica, 1990.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|