Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
18/08/2005 |
Data da última atualização: |
13/03/2023 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
TREVISAN, L. C.; VIEIRA, E. C.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. |
Afiliação: |
LILIAN C. TREVIZAN, UFSCAR; EDIVAN C. VIEIRA, UFSCAR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; JOAQUIM A. NÓBREGA, UFSCAR. |
Título: |
Use of factorial design for evaluation of plasma conditions and comparison of two liquid sample introduction systems for an axially viewed inductively coupled plasma optical emission spectrometer. |
Ano de publicação: |
2005 |
Fonte/Imprenta: |
Spectrochimica Acta Part B: Atomic Stectroscopy, v. 60, n. 5, p. 575-581, 2005. |
DOI: |
10.1016/j.sab.2005.02.014 |
Idioma: |
Inglês |
Conteúdo: |
A factorial design was applied to evaluate plasma conditions employing the Mg II 280/Mg I 285 nm intensity ratio in an axially viewed inductively coupled plasma optical emission spectrometer using different sample introduction devices: a concentric or a V-groove nebulizer and a cyclonic or a Sturman-Masters spray chamber. Effects of nebulizer gas flow-rate on Mg II/Mg I ratio were different in each introduction system. Robust conditions were obtained at low nebulizer gas flow-rate when using concentric nebulizer with a cyclonic spray chamber or a concentric nebulizer and a Sturman-Masters spray chamber. However, when using a V-groove nebulizer with a Sturman-Masters spray chamber, Mg II/Mg I ratio increased at high nebulizer gas flow-rates. Recovery experiments for a milk standard reference material diluted in water-soluble tertiary amines in both robust and non-robust conditions indicated that the robust condition was reached at higher nebulizer gas flow-rates and led to better accuracy and precision when using a V-groove nebulizer. |
Palavras-Chave: |
Axially viewed; Factorial design; ICP OES; Mg II/Mg I; Sample introduction. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 01871naa a2200229 a 4500 001 1047185 005 2023-03-13 008 2005 bl uuuu u00u1 u #d 024 7 $a10.1016/j.sab.2005.02.014$2DOI 100 1 $aTREVISAN, L. C. 245 $aUse of factorial design for evaluation of plasma conditions and comparison of two liquid sample introduction systems for an axially viewed inductively coupled plasma optical emission spectrometer.$h[electronic resource] 260 $c2005 520 $aA factorial design was applied to evaluate plasma conditions employing the Mg II 280/Mg I 285 nm intensity ratio in an axially viewed inductively coupled plasma optical emission spectrometer using different sample introduction devices: a concentric or a V-groove nebulizer and a cyclonic or a Sturman-Masters spray chamber. Effects of nebulizer gas flow-rate on Mg II/Mg I ratio were different in each introduction system. Robust conditions were obtained at low nebulizer gas flow-rate when using concentric nebulizer with a cyclonic spray chamber or a concentric nebulizer and a Sturman-Masters spray chamber. However, when using a V-groove nebulizer with a Sturman-Masters spray chamber, Mg II/Mg I ratio increased at high nebulizer gas flow-rates. Recovery experiments for a milk standard reference material diluted in water-soluble tertiary amines in both robust and non-robust conditions indicated that the robust condition was reached at higher nebulizer gas flow-rates and led to better accuracy and precision when using a V-groove nebulizer. 653 $aAxially viewed 653 $aFactorial design 653 $aICP OES 653 $aMg II/Mg I 653 $aSample introduction 700 1 $aVIEIRA, E. C. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aNÓBREGA, J. A. 773 $tSpectrochimica Acta Part B: Atomic Stectroscopy$gv. 60, n. 5, p. 575-581, 2005.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |