|
|
Registros recuperados : 35 | |
4. | | SUNIGA, P. A. P.; FERREIRA, A. B. R.; JULIANO, R. S.; EGITO, A. A. do. Genotipagem e prospecção de SNPs no gene HSF1, relacionado à termotolerância em bovinos. In: JORNADA CIENTÍFICA EMBRAPA GADO DE CORTE, 10., 2014, Campo Grande, MS. [Anais da..]. Campo Grande, MS: Embrapa Gado de Corte, 2014. p. 84-85. 2 p. (Embrapa Gado de Corte. Documentos, 208). Comissão organizadora: Grácia Maria Soares Rosinha, Alexandra Rocha de Oliveir, Rodrigo Carvalho Alva. Biblioteca(s): Embrapa Gado de Corte. |
| |
5. | | AZEVEDO, E. O.; CASTRO, R. S.; TABOSA, I. M.; ALMEIDA, V. M.; SANTOS, L. P.; BANDEIRA, D. A.; ARAÚJO, M. D.; ALMEIDA, J. F.; NASCIMENTO, E. R. Comportamento da agalaxia contagiosa em caprinos e ovinos no Nordeste brasileiro. In: CONGRESSO LATINOAMERICANO DE BUIATRIA, 11.; CONGRESSO BRASILEIRO DE BUIATRIA, 5.; CONGRESSO NORDESTINO DE BUIATRIA, 3., 2003, Salvador. Sanidade, base da economia pecuária: programa final: livro de resumos. Salvador: Associação Brasileira de Buiatria, 2003. p. 71. ref. 157. Biblioteca(s): Embrapa Caprinos e Ovinos. |
| |
8. | | ABREU, L. S. de; BELLON, S.; TORRES, T. Z. Agroecologia em redes sóciotécnicas: inovação social para um novo modelo de agricultura familiar? In: CONGRESSO DA SOCIEDADE BRASILEIRA DE ECONOMIA, ADMINISTRAÇÃO E SOCIOLOGIA RURAL, 56., 2018, Campinas. Transformações recentes na agropecuária brasileira: desafios em gestão, inovação, sustentabilidade e inclusão social: anais. Brasília, DF: SOBER, 2018. Não paginado. Sober 2018. Biblioteca(s): Embrapa Meio Ambiente. |
| |
11. | | NICOLODELLI, G.; SENESI, G. S.; PERAZZOLI, I. L. de O.; MARANGONI, B. S.; BENITES, V. de M.; MILORI, D. M. B. P. Double pulse laser induced breakdown spectroscopy: A potential tool for the analysis of contaminants and macro/micronutrients in organic mineral fertilizers. Science of the Total Environment, [S. l.], v. 565, p. 1116-1123, 2016. Biblioteca(s): Embrapa Instrumentação; Embrapa Solos. |
| |
19. | | GAUDENCIO, C. de A.; OLIVEIRA, M. C. N. de. Estado de agregacao do solo, em rotacao de especies perenes e anuais em semeadura direta, para integracao agropecuaria, no Planalto Meridional do Parana. In: REUNIAO DE PESQUISA DE SOJA DA REGIAO CENTRAL DO BRASIL, 20., 1998, Londrina. Ata e resumos. Londrina: EMBRAPA-CNPSo, 1998. p.193. (EMBRAPA-CNPSo. Documentos, 121). Biblioteca(s): Embrapa Soja. |
| |
20. | | CARDOSO, M. J.; CARVALHO, H. W. L. de; LEAL, M. de L. da S.; SANTOS, M. X. dos S. Estabilidade de variedades e híbridos de milho no Estado do Piauí no ano agrícola de 1998/1999. Agrotrópica, v. 12, n. 3, p. 151-162, 2000. Trabalho apresentado no XXIII CONGRESSO NACIONAL DE MILHO E SORGO, Uberlândia, MG, 21 a 25 de maio de 2000. Pesquisa financiada com recursos do Convênio Embrapa/ Banco do Nordeste. Biblioteca(s): Embrapa Meio-Norte. |
| |
Registros recuperados : 35 | |
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Solos. Para informações adicionais entre em contato com cnps.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Instrumentação; Embrapa Solos. |
Data corrente: |
07/06/2016 |
Data da última atualização: |
28/06/2018 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 1 |
Autoria: |
NICOLODELLI, G.; SENESI, G. S.; PERAZZOLI, I. L. de O.; MARANGONI, B. S.; BENITES, V. de M.; MILORI, D. M. B. P. |
Afiliação: |
DEBORA MARCONDES BASTOS PEREIRA, CNPDIA. |
Título: |
Double pulse laser induced breakdown spectroscopy: A potential tool for the analysis of contaminants and macro/micronutrients in organic mineral fertilizers. |
Ano de publicação: |
2016 |
Fonte/Imprenta: |
Science of the Total Environment, [S. l.], v. 565, p. 1116-1123, 2016. |
DOI: |
https://doi.org/10.1016/j.scitotenv.2016.05.153 |
Idioma: |
Inglês |
Conteúdo: |
Organic fertilizers are obtained from waste of plant or animal origin. One of the advantages of organic fertilizers is that, from the composting, it recycles waste-organic of urban and agriculture origin, whose disposal would cause environmental impacts. Fast and accurate analysis of both major and minor/trace elements contained in organic mineral and inorganic fertilizers of new generation have promoted the application of modern analytical techniques. In particular, laser induced breakdown spectroscopy (LIBS) is showing to be a very promising, quick and practical technique to detect and measure contaminants and nutrients in fertilizers. Although, this technique presents some limitations, such as a low sensitivity, if compared to other spectroscopic techniques, the use of double pulse (DP) LIBS is an alternative to the conventional LIBS in single pulse (SP). The macronutrients (Ca, Mg, K, P), micronutrients (Cu, Fe, Na, Mn, Zn) and contaminant (Cr) in fertilizer using LIBS in SP and DP configurations were evaluated. A comparative study for both configurations was performed using optimized key parameters for improving LIBS performance. The limit of detection (LOD) values obtained by DP LIBS increased up to seven times as compared to SP LIBS. In general, the marked improvement obtained when using DP system in the simultaneous LIBS quantitative determination for fertilizers analysis could be ascribed to the larger ablated mass of the sample. The results presented in this study show the promising potential of the DP LIBS technique for a qualitative analysis in fertilizers, without requiring sample preparation with chemical reagents. MenosOrganic fertilizers are obtained from waste of plant or animal origin. One of the advantages of organic fertilizers is that, from the composting, it recycles waste-organic of urban and agriculture origin, whose disposal would cause environmental impacts. Fast and accurate analysis of both major and minor/trace elements contained in organic mineral and inorganic fertilizers of new generation have promoted the application of modern analytical techniques. In particular, laser induced breakdown spectroscopy (LIBS) is showing to be a very promising, quick and practical technique to detect and measure contaminants and nutrients in fertilizers. Although, this technique presents some limitations, such as a low sensitivity, if compared to other spectroscopic techniques, the use of double pulse (DP) LIBS is an alternative to the conventional LIBS in single pulse (SP). The macronutrients (Ca, Mg, K, P), micronutrients (Cu, Fe, Na, Mn, Zn) and contaminant (Cr) in fertilizer using LIBS in SP and DP configurations were evaluated. A comparative study for both configurations was performed using optimized key parameters for improving LIBS performance. The limit of detection (LOD) values obtained by DP LIBS increased up to seven times as compared to SP LIBS. In general, the marked improvement obtained when using DP system in the simultaneous LIBS quantitative determination for fertilizers analysis could be ascribed to the larger ablated mass of the sample. The results presented in this study ... Mostrar Tudo |
Palavras-Chave: |
Fertilizante orgânico; Limite de detecção. |
Thesagro: |
Adubo Orgânico; Resíduo Orgânico. |
Categoria do assunto: |
-- P Recursos Naturais, Ciências Ambientais e da Terra |
Marc: |
LEADER 02516naa a2200241 a 4500 001 2063625 005 2018-06-28 008 2016 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.1016/j.scitotenv.2016.05.153$2DOI 100 1 $aNICOLODELLI, G. 245 $aDouble pulse laser induced breakdown spectroscopy$bA potential tool for the analysis of contaminants and macro/micronutrients in organic mineral fertilizers.$h[electronic resource] 260 $c2016 520 $aOrganic fertilizers are obtained from waste of plant or animal origin. One of the advantages of organic fertilizers is that, from the composting, it recycles waste-organic of urban and agriculture origin, whose disposal would cause environmental impacts. Fast and accurate analysis of both major and minor/trace elements contained in organic mineral and inorganic fertilizers of new generation have promoted the application of modern analytical techniques. In particular, laser induced breakdown spectroscopy (LIBS) is showing to be a very promising, quick and practical technique to detect and measure contaminants and nutrients in fertilizers. Although, this technique presents some limitations, such as a low sensitivity, if compared to other spectroscopic techniques, the use of double pulse (DP) LIBS is an alternative to the conventional LIBS in single pulse (SP). The macronutrients (Ca, Mg, K, P), micronutrients (Cu, Fe, Na, Mn, Zn) and contaminant (Cr) in fertilizer using LIBS in SP and DP configurations were evaluated. A comparative study for both configurations was performed using optimized key parameters for improving LIBS performance. The limit of detection (LOD) values obtained by DP LIBS increased up to seven times as compared to SP LIBS. In general, the marked improvement obtained when using DP system in the simultaneous LIBS quantitative determination for fertilizers analysis could be ascribed to the larger ablated mass of the sample. The results presented in this study show the promising potential of the DP LIBS technique for a qualitative analysis in fertilizers, without requiring sample preparation with chemical reagents. 650 $aAdubo Orgânico 650 $aResíduo Orgânico 653 $aFertilizante orgânico 653 $aLimite de detecção 700 1 $aSENESI, G. S. 700 1 $aPERAZZOLI, I. L. de O. 700 1 $aMARANGONI, B. S. 700 1 $aBENITES, V. de M. 700 1 $aMILORI, D. M. B. P. 773 $tScience of the Total Environment, [S. l.]$gv. 565, p. 1116-1123, 2016.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|