|
|
Registros recuperados : 1 | |
Registros recuperados : 1 | |
|
|
Registro Completo
Biblioteca(s): |
Embrapa Solos. |
Data corrente: |
18/03/2024 |
Data da última atualização: |
18/03/2024 |
Tipo da produção científica: |
Artigo em Anais de Congresso |
Autoria: |
TAVARES, S. R. de L.; RODRIGUES, N. F.; CORRÊA, G. M. |
Afiliação: |
SILVIO ROBERTO DE LUCENA TAVARES, CNPS; NATÁLIA FERNANDES RODRIGUES, UNIVERSIDADE FEDERAL RURAL DO RIO DE JANEIRO; GABRIELA MARTINS CORRÊA, UNIVERSIDADE FEDERAL FLUMINENSE. |
Título: |
Use of low-cost class a evapotranspiration pan for reference evapotranspiration estimation in protected and field environments. |
Ano de publicação: |
2023 |
Fonte/Imprenta: |
In: WORKSHOP ON BIOSYSTEMS ENGINEERING - WEB 9.0, 9., 2023, Niterói. Proceedings [...]. Niterói: AGRHA Consulting, 2023. p. 111-117. |
Idioma: |
Inglês |
Conteúdo: |
Currently, there are various methods for determining the Class A pan coefficient (Kp) in estimating reference evapotranspiration (ETo), which is of utmost importance for water management in agriculture. This study aimed to estimate ETo inside and outside agricultural greenhouses using a low-cost constructed Class A pan (TCA-c) method. To estimate ETo, it is necessary to establish the Kp, as ETo is the product of ECA multiplied by Kp. This study employed the calibration method, comparing ETo determined by Penman-Monteith (EToPM) with Class A pan evaporation (ECA) to determine Kp. EToPM served as the standard for correlations with reference evapotranspiration using the TCA-c method inside and outside an agricultural greenhouse, avoiding the installation of a "Class A" pan inside the greenhouse. The experiment was conducted at UFF's Gragoatá campus in Niterói - RJ. Four TCA-c pans were installed (three inside and one outside an agricultural greenhouse) and managed for one year. Principal Component Analyses (PCA) revealed significant differences in ETo throughout the seasons. Adjusted Kps were established for all pans. It was observed that ETo inside the greenhouse was lower than that estimated outside. It is recommended to install the TCA-c pan inside the greenhouse for ETo estimation, utilizing different Kps throughout the seasons. |
Palavras-Chave: |
Class A Pan; Pan coefficient; Reference evapotranspiration. |
Thesagro: |
Evapotranspiração. |
Categoria do assunto: |
P Recursos Naturais, Ciências Ambientais e da Terra |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/doc/1162925/1/Use-of-low-cost-class-a-evapotranspiration-pan-2023.pdf
|
Marc: |
LEADER 02058nam a2200181 a 4500 001 2162925 005 2024-03-18 008 2023 bl uuuu u00u1 u #d 100 1 $aTAVARES, S. R. de L. 245 $aUse of low-cost class a evapotranspiration pan for reference evapotranspiration estimation in protected and field environments.$h[electronic resource] 260 $aIn: WORKSHOP ON BIOSYSTEMS ENGINEERING - WEB 9.0, 9., 2023, Niterói. Proceedings [...]. Niterói: AGRHA Consulting, 2023. p. 111-117.$c2023 520 $aCurrently, there are various methods for determining the Class A pan coefficient (Kp) in estimating reference evapotranspiration (ETo), which is of utmost importance for water management in agriculture. This study aimed to estimate ETo inside and outside agricultural greenhouses using a low-cost constructed Class A pan (TCA-c) method. To estimate ETo, it is necessary to establish the Kp, as ETo is the product of ECA multiplied by Kp. This study employed the calibration method, comparing ETo determined by Penman-Monteith (EToPM) with Class A pan evaporation (ECA) to determine Kp. EToPM served as the standard for correlations with reference evapotranspiration using the TCA-c method inside and outside an agricultural greenhouse, avoiding the installation of a "Class A" pan inside the greenhouse. The experiment was conducted at UFF's Gragoatá campus in Niterói - RJ. Four TCA-c pans were installed (three inside and one outside an agricultural greenhouse) and managed for one year. Principal Component Analyses (PCA) revealed significant differences in ETo throughout the seasons. Adjusted Kps were established for all pans. It was observed that ETo inside the greenhouse was lower than that estimated outside. It is recommended to install the TCA-c pan inside the greenhouse for ETo estimation, utilizing different Kps throughout the seasons. 650 $aEvapotranspiração 653 $aClass A Pan 653 $aPan coefficient 653 $aReference evapotranspiration 700 1 $aRODRIGUES, N. F. 700 1 $aCORRÊA, G. M.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Solos (CNPS) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|