|
|
Registros recuperados : 171 | |
2. | | TREVISAN, L. C.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Acid vapor partial digestion of biological samples in a focused microwave: multielement determination by ICP OES with axially-viewed configuration. In: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 7., 2002, Florianópolis, SC. ICP Information Newsletter, v.28, n.1, june 2002. p.136. Tu34. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
5. | | SANTOS, D. M.; NOGUEIRA, A. R. de A.; NEVES, E. F. A.; NÓBREGA, J. A. Análise química e simulação do reagente CFA-C. In: ENCONTRO REGIONAL DE QUÍMICA DA SOCIEDADE BRASILEIRA DE QUÍMICA, 13.; SEMANA DA QUÍMICA, 31., 2001, Jaboticabal, SP. Anais... Jaboticabal: Instituto de Química-UNESP, 2001. p.70. QA-8. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
10. | | GARCIA, E. E.; PEREIRA, C. D.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Avaliação da correção de sinais de fundo causados pelos íons diatômicos Ar2 + e CN+ em ICP-MS com interface CRI. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 15.; CONGRESSO IBEROAMERICANO DE QUÍMICA ANALÍTICA, 3., 2009, Salvador, BA. Anais... Salvador: SBQ: UFBA, 2009. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
16. | | SILVA, H. O.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Extração assistida por ultra-som de Al, Ca, Mg e Mn em amostras de chás. In: REUNIÃO ANUAL DA SOCIEDADE DE BRASILEIRA DE QUÍMICA, 26., 2003, Poços de Caldas, MG. Livros de resumos... Poços de Caldas: SBQ, 2003. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
19. | | SILVA, F. V.; SILVA, C. S.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Evaluation of inductively coupled plasma optical emission spectrometers with axially-and radially-viewed configurations. In: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 7., 2002, Florianópolis, SC. ICP Information Newsletter, v.28, n.1, jun. 2002. 2 p. Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 171 | |
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
04/10/2010 |
Data da última atualização: |
30/06/2023 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 1 |
Autoria: |
PEREIRA, C. D.; GARCIA, E. E.; SILVA, F. V.; NOGUEIRA, A. R. de A.; NOBREGA, J. A. |
Afiliação: |
CATARINIE D. PEREIRA,, UFSCar/SÃO CARLOS, SP; EDIVALDO E. GARCIA, UNIV. ESTADUAL DE MARINGÁ,MARINGÁ,PR.; FERNANDO V. SILVA, NESTLÉ DO BRASIL/SÃO PAULO; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; JOAQUIM A. NOBREGA, UFSCar/SÃO CARLOS, SP. |
Título: |
Behaviour of arsenic and selenium in an ICP-QMS with collision and reaction interface. |
Ano de publicação: |
2010 |
Fonte/Imprenta: |
Journal of Analytical Atomic Spectrometry, |
Idioma: |
Português |
Conteúdo: |
The performance of a collision reaction interface (CRI) for minimization of spectral interferences on analytical signals of 75As+ and 76Se+, 77Se+, 78Se+, 80Se+ and 82Se+ isotopes was evaluated by using H2 and He gases introduced through the sampler or skimmer cones of an inductively coupled plasma quadrupole mass spectrometer (ICP-QMS). Different gas flow rates were tested employing reference solutions prepared either in hydrochloric acid or in water soluble tertiary amines (CFA-C) media as carbon source. A hydrogen gas flow rate at 60 mL min1 introduced through skimmer cone was effective for minimizing polyatomic interferences on 75As+ and Se isotopes, except for 80Se+. The use of He introduced through sampler or skimmer cones had a minor effect on the minimization of interferences when compared to the use of H2 gas. Moreover, it was observed that the gas introduction through the sampler cone had no effect on interferences when using gas flow rates up to 80 mL min1 for both gases evaluated. Based on these results, it can be recommended to use H2 gas introduced through skimmer cone of the CRI for correcting polyatomic interferences on 75As+ and Se isotopes in matrixes containing up to 2% v v1 chloride. |
Palavras-Chave: |
ICP-QMS. |
Thesaurus NAL: |
arsenic; selenium. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 01798naa a2200205 a 4500 001 1863510 005 2023-06-30 008 2010 bl uuuu u00u1 u #d 100 1 $aPEREIRA, C. D. 245 $aBehaviour of arsenic and selenium in an ICP-QMS with collision and reaction interface.$h[electronic resource] 260 $c2010 520 $aThe performance of a collision reaction interface (CRI) for minimization of spectral interferences on analytical signals of 75As+ and 76Se+, 77Se+, 78Se+, 80Se+ and 82Se+ isotopes was evaluated by using H2 and He gases introduced through the sampler or skimmer cones of an inductively coupled plasma quadrupole mass spectrometer (ICP-QMS). Different gas flow rates were tested employing reference solutions prepared either in hydrochloric acid or in water soluble tertiary amines (CFA-C) media as carbon source. A hydrogen gas flow rate at 60 mL min1 introduced through skimmer cone was effective for minimizing polyatomic interferences on 75As+ and Se isotopes, except for 80Se+. The use of He introduced through sampler or skimmer cones had a minor effect on the minimization of interferences when compared to the use of H2 gas. Moreover, it was observed that the gas introduction through the sampler cone had no effect on interferences when using gas flow rates up to 80 mL min1 for both gases evaluated. Based on these results, it can be recommended to use H2 gas introduced through skimmer cone of the CRI for correcting polyatomic interferences on 75As+ and Se isotopes in matrixes containing up to 2% v v1 chloride. 650 $aarsenic 650 $aselenium 653 $aICP-QMS 700 1 $aGARCIA, E. E. 700 1 $aSILVA, F. V. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aNOBREGA, J. A. 773 $tJournal of Analytical Atomic Spectrometry
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|