|
|
Registro Completo |
Biblioteca(s): |
Embrapa Instrumentação. |
Data corrente: |
22/12/1999 |
Data da última atualização: |
09/03/2010 |
Autoria: |
CARVALHO, A. A.; MASCARENHAS, S.; PAULA, M. H. de. |
Afiliação: |
UNESP-Campus de Ilha Solteira; EMBRAPA-CNPDIA. |
Título: |
A new pulsed photoacoustical radiation dosimeter. |
Ano de publicação: |
1988 |
Fonte/Imprenta: |
In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988. |
Páginas: |
p.II-26. |
Idioma: |
Inglês |
Conteúdo: |
We describe a new method to measure X-rays in its diagnostic region using a new photoacoustical radiation dosimeter. We measure the exposure rate and the energy fluence rate without the necessity to use synchronous detection. The measurement is made determining with a recorder, oscilloscope or electronic peak detector the amplitude of the electrical pulses produced when a chopped X-ray beam strikes a 0,6mm thick Pb detecting sample inside a photoacoustical cell. The pulsed photoacoustical radiation dosimeter (PPARD) consists of an X-ray beam commutator, a photoacoustical cell, a pre-amplifier and an electronic peak detector, oscilloscope or recorder. The PPARD has the following characteristics for diagnostic X-ray beam: 1) it has a linear response with the energy fluence rate; 2) the photoacoustic cell is simple to construct; 3) the instrumentation is inexpensive and easily available; 4) the lower detection limit of energy fluence rate range is 0,42W/m2; 5) the lower detection limit of exposure rate range is 2,0.10E-4 C.KgE-1.sE-1 (0,78 R/s). |
Palavras-Chave: |
Dosimeter; Photoacoustical; Pulsed; Radiation. |
Categoria do assunto: |
-- |
Marc: |
LEADER 01656naa a2200205 a 4500 001 1026546 005 2010-03-09 008 1988 bl --- 0-- u #d 100 1 $aCARVALHO, A. A. 245 $aA new pulsed photoacoustical radiation dosimeter. 260 $c1988 300 $ap.II-26. 520 $aWe describe a new method to measure X-rays in its diagnostic region using a new photoacoustical radiation dosimeter. We measure the exposure rate and the energy fluence rate without the necessity to use synchronous detection. The measurement is made determining with a recorder, oscilloscope or electronic peak detector the amplitude of the electrical pulses produced when a chopped X-ray beam strikes a 0,6mm thick Pb detecting sample inside a photoacoustical cell. The pulsed photoacoustical radiation dosimeter (PPARD) consists of an X-ray beam commutator, a photoacoustical cell, a pre-amplifier and an electronic peak detector, oscilloscope or recorder. The PPARD has the following characteristics for diagnostic X-ray beam: 1) it has a linear response with the energy fluence rate; 2) the photoacoustic cell is simple to construct; 3) the instrumentation is inexpensive and easily available; 4) the lower detection limit of energy fluence rate range is 0,42W/m2; 5) the lower detection limit of exposure rate range is 2,0.10E-4 C.KgE-1.sE-1 (0,78 R/s). 653 $aDosimeter 653 $aPhotoacoustical 653 $aPulsed 653 $aRadiation 700 1 $aMASCARENHAS, S. 700 1 $aPAULA, M. H. de 773 $tIn: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Recursos Genéticos e Biotecnologia. Para informações adicionais entre em contato com cenargen.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Recursos Genéticos e Biotecnologia. |
Data corrente: |
28/02/2001 |
Data da última atualização: |
23/09/2014 |
Autoria: |
BUSO, G. S. C.; BRONDANI, R. V.; AMARAL, Z. P. de S.; REIS, A. M. M.; FERREIRA, M. E. |
Afiliação: |
Embrapa Recursos Geneticos e Biotecnologia. |
Título: |
Desenvolivmento de primers SSR para analise genetica de pimentas e pimentoes (Capsicum spp.) utilizando biblioteca genomica enriquecida. |
Ano de publicação: |
2000 |
Fonte/Imprenta: |
Brasilia: Embrapa Recursos Geneticos e Biotecnologia, 2000 |
Páginas: |
27p. |
Série: |
(Embrapa Recursos Geneticos e Biotecnologia. Boletim de Pesquisa, 15) |
Idioma: |
Português |
Palavras-Chave: |
Biblioteca genomica; Microssatelites; PCR ancorado. |
Thesaurus NAL: |
Capsicum. |
Categoria do assunto: |
-- |
Marc: |
LEADER 00741nam a2200217 a 4500 001 1179922 005 2014-09-23 008 2000 bl uuuu u0uu1 u #d 100 1 $aBUSO, G. S. C. 245 $aDesenvolivmento de primers SSR para analise genetica de pimentas e pimentoes (Capsicum spp.) utilizando biblioteca genomica enriquecida. 260 $aBrasilia: Embrapa Recursos Geneticos e Biotecnologia$c2000 300 $a27p. 490 $a(Embrapa Recursos Geneticos e Biotecnologia. Boletim de Pesquisa, 15) 650 $aCapsicum 653 $aBiblioteca genomica 653 $aMicrossatelites 653 $aPCR ancorado 700 1 $aBRONDANI, R. V. 700 1 $aAMARAL, Z. P. de S. 700 1 $aREIS, A. M. M. 700 1 $aFERREIRA, M. E.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Recursos Genéticos e Biotecnologia (CENARGEN) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|