|
|
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
11/07/2014 |
Data da última atualização: |
20/03/2023 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
CRISPINO, C. C.; LEMOS, S. G.; KANOGAWA, M. Y.; NOGUEIRA, A. R. de A. |
Afiliação: |
CARLA CRIPA CRISPINO, CNTRO DE ENERGIA NUCLEAR/PIRACICABA; SHERLAN GUIMARÃES LEMOS, UNIVERSIDADE FEDERAL DA PARAÍBA, JOÃO PESSOA; MARCOS YASSUO KAMOGAWA, ESALQ/PIRACICABA; ANA RITA DE ARAUJO NOGUEIRA, CPPSE. |
Título: |
Simultaneous determination of arsenic, antimony and selenium in agronomic samples by hydride generation and optical emission spectrometry. |
Ano de publicação: |
2013 |
Fonte/Imprenta: |
Brazilian Journal of Analitical Chemistry, v. 10, p. 460-467, 2013. |
Idioma: |
Inglês |
Conteúdo: |
A continuous-fl ow hydride generation system was developed and used with inductively coupled plasma optical emission spectrometry (ICP OES) for simultaneous determination of As, Sb and Se in agronomic samples. A factorial design was applied in order to establish the best chemical and instrumental conditions. The factors chosen for evaluation were: reagent concentration, plasma power, carrier gas fl ow rate, and the viewing height of the plasma. The LODs of the method were 0.124, 0.168, and 0.141 ?g L-1 for As, Sb, and Se, respectively. The RSD (relative standard derivation) was lower than 1.8%, and the sampling throughput was 40 samples h-1 . To check the method accuracy, eight different kinds of agronomic samples - for- age, corn silage, mineral salt, and bovine-derived samples (blood, viscera, carcass, meat, and semen) - were spiked with different analyte concentrations (at the ?g L-1 level). Recoveries ranged from 90 to 102%. |
Palavras-Chave: |
Agronomic sample; Factorial design; Hydride generation; Inductively coupled; Spectrometry. |
Categoria do assunto: |
W Química e Física |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/104956/1/PROCI-2014.00034.pdf
|
Marc: |
LEADER 01661naa a2200217 a 4500 001 1990422 005 2023-03-20 008 2013 bl uuuu u00u1 u #d 100 1 $aCRISPINO, C. C. 245 $aSimultaneous determination of arsenic, antimony and selenium in agronomic samples by hydride generation and optical emission spectrometry.$h[electronic resource] 260 $c2013 520 $aA continuous-fl ow hydride generation system was developed and used with inductively coupled plasma optical emission spectrometry (ICP OES) for simultaneous determination of As, Sb and Se in agronomic samples. A factorial design was applied in order to establish the best chemical and instrumental conditions. The factors chosen for evaluation were: reagent concentration, plasma power, carrier gas fl ow rate, and the viewing height of the plasma. The LODs of the method were 0.124, 0.168, and 0.141 ?g L-1 for As, Sb, and Se, respectively. The RSD (relative standard derivation) was lower than 1.8%, and the sampling throughput was 40 samples h-1 . To check the method accuracy, eight different kinds of agronomic samples - for- age, corn silage, mineral salt, and bovine-derived samples (blood, viscera, carcass, meat, and semen) - were spiked with different analyte concentrations (at the ?g L-1 level). Recoveries ranged from 90 to 102%. 653 $aAgronomic sample 653 $aFactorial design 653 $aHydride generation 653 $aInductively coupled 653 $aSpectrometry 700 1 $aLEMOS, S. G. 700 1 $aKANOGAWA, M. Y. 700 1 $aNOGUEIRA, A. R. de A. 773 $tBrazilian Journal of Analitical Chemistry$gv. 10, p. 460-467, 2013.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 1 | |
Registros recuperados : 1 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|