Título: |
Thermal environment of table grape packing houses in the São Francisco Valley. |
Ano de publicação: |
2017 |
Fonte/Imprenta: |
Engenharia Agrícola, Jaboticabal, v. 37, n. 1, p. 35-45, jan./fev. 2017. |
ISSN: |
1809-4430 |
DOI: |
10.1590/1809-4430-Eng.Agric.v37n1p35-45/2017 |
Idioma: |
Inglês |
Conteúdo: |
The aim of this study was to characterize the thermal environment of the sorting and packing sectors of small, medium and large packing houses in the São Francisco Valley, Northeast of Brazil. Micrometeorological data were monitored every 15 minutes for 20 days during winter 2014 and summer 2015. The parameters evaluated were air temperature (oC), relative humidity (%) and radiant thermal load, RTL,(W/m2). External environmental data were obtained from weather stations close to the packing houses. The data obtained show that packing houses minimum and maximum temperatures were reached at 6am and 3pm, respectively, during winter and summer. Both seasons had air temperatures above 20°C, relative humidity below 90% and radiant thermal load above 450 W/m2. The construction materials that had the highest energy transmissions were the roofs. Metal roofs had the worst thermal conditioning, resulting in maximum internal air temperatures of 32.7°C and minimum relative humidity of 40.9% at 3pm, during summer. According to the results, thermal environments of sorting and packing sectors proved to be inadequate for processing table grapes, mainly during summer. These packing houses should be modified to reach the optimal thermal environment, considering the regional climatic conditions. |
Palavras-Chave: |
Agricultural facilities; Ambiente térmicos; Instalações agrícolas; Thermal environment; Uva de mesa; Vale de são francisco. |
Thesagro: |
Uva; Vitis Vinifera. |
Thesaurus Nal: |
Grapes. |
Categoria do assunto: |
A Sistemas de Cultivo |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/160782/1/Tonetto-3-2017.pdf
|
Marc: |
LEADER 02202naa a2200301 a 4500 001 2070927 005 2018-01-24 008 2017 bl uuuu u00u1 u #d 022 $a1809-4430 024 7 $a10.1590/1809-4430-Eng.Agric.v37n1p35-45/2017$2DOI 100 1 $aVASCONCELOS, O. 245 $aThermal environment of table grape packing houses in the São Francisco Valley.$h[electronic resource] 260 $c2017 520 $aThe aim of this study was to characterize the thermal environment of the sorting and packing sectors of small, medium and large packing houses in the São Francisco Valley, Northeast of Brazil. Micrometeorological data were monitored every 15 minutes for 20 days during winter 2014 and summer 2015. The parameters evaluated were air temperature (oC), relative humidity (%) and radiant thermal load, RTL,(W/m2). External environmental data were obtained from weather stations close to the packing houses. The data obtained show that packing houses minimum and maximum temperatures were reached at 6am and 3pm, respectively, during winter and summer. Both seasons had air temperatures above 20°C, relative humidity below 90% and radiant thermal load above 450 W/m2. The construction materials that had the highest energy transmissions were the roofs. Metal roofs had the worst thermal conditioning, resulting in maximum internal air temperatures of 32.7°C and minimum relative humidity of 40.9% at 3pm, during summer. According to the results, thermal environments of sorting and packing sectors proved to be inadequate for processing table grapes, mainly during summer. These packing houses should be modified to reach the optimal thermal environment, considering the regional climatic conditions. 650 $aGrapes 650 $aUva 650 $aVitis Vinifera 653 $aAgricultural facilities 653 $aAmbiente térmicos 653 $aInstalações agrícolas 653 $aThermal environment 653 $aUva de mesa 653 $aVale de são francisco 700 1 $aTURCO, S. H. N. 700 1 $aDACANAL, C. 700 1 $aLUZ, S. 700 1 $aFREITAS, S. T. de 773 $tEngenharia Agrícola, Jaboticabal$gv. 37, n. 1, p. 35-45, jan./fev. 2017.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Semiárido (CPATSA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 1 | |
1. | | VASCONCELOS, O.; TURCO, S. H. N.; DACANAL, C.; LUZ, S.; FREITAS, S. T. de. Thermal environment of table grape packing houses in the São Francisco Valley. Engenharia Agrícola, Jaboticabal, v. 37, n. 1, p. 35-45, jan./fev. 2017.Tipo: Artigo em Periódico Indexado | Circulação/Nível: B - 1 |
Biblioteca(s): Embrapa Semiárido. |
| |
Registros recuperados : 1 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|