Título: |
Evaluation of inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations. |
Ano de publicação: |
2002 |
Fonte/Imprenta: |
Spectrochimica Acta Part B, v.57, n.12, p.1905-1913, dec. 2002. |
DOI: |
https://doi.org/10.1016/S0584-8547(02)00176-3 |
Idioma: |
Inglês |
Conteúdo: |
The analytical performance of two inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations, equipped with charge coupled device solid-state detectors was evaluated using Ar, Ba, Mg, and Ni as test elements. Both instruments have similar Echelle optical arrangements and radio-frequency generators, differing only in the viewing mode and in the diameter of the central injector tube, i.e. 2.3 for the axially and 1.4 mm for the radially viewed ICP. The figures of merit evaluated were: warm-up time, short- and long-term stabilities, UV and VIS spectral resolution and limit of detection (LOD) for Ni in 0.14 mol l-1 HNO3 and 1000 mg l-1 Cr media, respectively. The influence of residual carbon content on background equivalent concentration (BEC) and sensitivity attained for Al, As, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Se and Zn was also investigated in both viewing modes. The robustness, short- and long-term stabilities, and UV and VIS spectral resolutions were similar for both configurations. For the radially viewed equipment, the warm-up time was at least a factor of 2 shorter than that for the axially viewed configuration. On the other hand, the sensitivity attained for Ni with the axially viewed arrangement was approximately 20 times better than that with the radially viewed. In both viewing modes, and for most of the evaluated elements, the values of BEC and LOD were similar for all studied carbon concentrations (from 10 to 10 000 mg l-1 C) when working with robust plasma conditions. The Mg II/Mg I ratio at an applied power of 1.3 kW and a nebulizer gas flow-rate of 0.90 and 0.70 l min-1 for axially and radially viewed configurations were 10.6 and 13.7, respectively. Quantitative determinations were successfully performed using both systems. MenosThe analytical performance of two inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations, equipped with charge coupled device solid-state detectors was evaluated using Ar, Ba, Mg, and Ni as test elements. Both instruments have similar Echelle optical arrangements and radio-frequency generators, differing only in the viewing mode and in the diameter of the central injector tube, i.e. 2.3 for the axially and 1.4 mm for the radially viewed ICP. The figures of merit evaluated were: warm-up time, short- and long-term stabilities, UV and VIS spectral resolution and limit of detection (LOD) for Ni in 0.14 mol l-1 HNO3 and 1000 mg l-1 Cr media, respectively. The influence of residual carbon content on background equivalent concentration (BEC) and sensitivity attained for Al, As, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Se and Zn was also investigated in both viewing modes. The robustness, short- and long-term stabilities, and UV and VIS spectral resolutions were similar for both configurations. For the radially viewed equipment, the warm-up time was at least a factor of 2 shorter than that for the axially viewed configuration. On the other hand, the sensitivity attained for Ni with the axially viewed arrangement was approximately 20 times better than that with the radially viewed. In both viewing modes, and for most of the evaluated elements, the values of BEC and LOD were similar for all studied carbon concentrations (from 10 to 10 000 mg l... Mostrar Tudo |
Palavras-Chave: |
Axial viewing; Figures of merit; ICP OES; Radial viewing. |
Categoria do assunto: |
W Química e Física |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/48494/1/PROCIARAN2002.00181.pdf
|
Marc: |
LEADER 02556naa a2200229 a 4500 001 1046350 005 2022-06-20 008 2002 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.1016/S0584-8547(02)00176-3$2DOI 100 1 $aSILVA, F. V. 245 $aEvaluation of inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations.$h[electronic resource] 260 $c2002 520 $aThe analytical performance of two inductively coupled plasma optical emission spectrometers with axially and radially viewed configurations, equipped with charge coupled device solid-state detectors was evaluated using Ar, Ba, Mg, and Ni as test elements. Both instruments have similar Echelle optical arrangements and radio-frequency generators, differing only in the viewing mode and in the diameter of the central injector tube, i.e. 2.3 for the axially and 1.4 mm for the radially viewed ICP. The figures of merit evaluated were: warm-up time, short- and long-term stabilities, UV and VIS spectral resolution and limit of detection (LOD) for Ni in 0.14 mol l-1 HNO3 and 1000 mg l-1 Cr media, respectively. The influence of residual carbon content on background equivalent concentration (BEC) and sensitivity attained for Al, As, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Se and Zn was also investigated in both viewing modes. The robustness, short- and long-term stabilities, and UV and VIS spectral resolutions were similar for both configurations. For the radially viewed equipment, the warm-up time was at least a factor of 2 shorter than that for the axially viewed configuration. On the other hand, the sensitivity attained for Ni with the axially viewed arrangement was approximately 20 times better than that with the radially viewed. In both viewing modes, and for most of the evaluated elements, the values of BEC and LOD were similar for all studied carbon concentrations (from 10 to 10 000 mg l-1 C) when working with robust plasma conditions. The Mg II/Mg I ratio at an applied power of 1.3 kW and a nebulizer gas flow-rate of 0.90 and 0.70 l min-1 for axially and radially viewed configurations were 10.6 and 13.7, respectively. Quantitative determinations were successfully performed using both systems. 653 $aAxial viewing 653 $aFigures of merit 653 $aICP OES 653 $aRadial viewing 700 1 $aTREVIZAN, L. C. 700 1 $aSILVA, C. S. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aNÓBREGA, J. A. 773 $tSpectrochimica Acta Part B$gv.57, n.12, p.1905-1913, dec. 2002.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Acre. Para informações adicionais entre em contato com cpafac.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Acre. |
Data corrente: |
14/07/2009 |
Data da última atualização: |
08/11/2023 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
FAZOLIN, M.; COSTA, C. R. da; ESTRELA, J. L. V.; DAMACENO, J. E. dE O.; ALBUQUERQUE, E. S. de; CAVALCANTE, A. S. da S. |
Afiliação: |
MURILO FAZOLIN, CPAF-AC; CHARLES RODRIGUES DA COSTA, CPAF-AC; JOELMA LIMA VIDAL ESTRELA, CNPq/Embrapa Acre; JANAINA ESTEVO DE OLIVEIRA DAMACENO, PIBIC/Embrapa Acre; ELIZÂNGELA SAMPAIO DE ALBUQUERQUE, Programa Biodiversidade Brasíl Itália; ANA SUZETTE DA SILVA CAVALCANTE, BOLSISTA CNPq/EMBRAPA ACRE. |
Título: |
Adequação do uso dos talos de Tanaecium nocturnum para controle de adultos de Sitophilus zeamais (Coleoptera: curculionidae) em milho armazenado em paiol. |
Ano de publicação: |
2009 |
Fonte/Imprenta: |
In: SIMPÓSIO DE CONTROLE BIOLÓGICO, 11., 2009, Bento Gonçalves. Tecnologia e conservação ambiental: resumos. Bento Gonçalves: Sociedade Entomológica do Brasil: IRGA: Unisinos: Fiocruz, 2009. |
Páginas: |
1 p. |
Descrição Física: |
1 CD-ROM. |
Idioma: |
Português |
Palavras-Chave: |
Tanaecium. |
Thesagro: |
Armazenamento de Alimento; Gorgulho do Milho; Milho; Paiol; Praga de Planta; Sitophilus Zeamais; Zea Mays. |
Categoria do assunto: |
O Insetos e Entomologia |
Marc: |
LEADER 01011nam a2200265 a 4500 001 1511425 005 2023-11-08 008 2009 bl uuuu u00u1 u #d 100 1 $aFAZOLIN, M. 245 $aAdequação do uso dos talos de Tanaecium nocturnum para controle de adultos de Sitophilus zeamais (Coleoptera$bcurculionidae) em milho armazenado em paiol.$h[electronic resource] 260 $aIn: SIMPÓSIO DE CONTROLE BIOLÓGICO, 11., 2009, Bento Gonçalves. Tecnologia e conservação ambiental: resumos. Bento Gonçalves: Sociedade Entomológica do Brasil: IRGA: Unisinos: Fiocruz$c2009 300 $a1 p.$c1 CD-ROM. 650 $aArmazenamento de Alimento 650 $aGorgulho do Milho 650 $aMilho 650 $aPaiol 650 $aPraga de Planta 650 $aSitophilus Zeamais 650 $aZea Mays 653 $aTanaecium 700 1 $aCOSTA, C. R. da 700 1 $aESTRELA, J. L. V. 700 1 $aDAMACENO, J. E. dE O. 700 1 $aALBUQUERQUE, E. S. de 700 1 $aCAVALCANTE, A. S. da S.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Acre (CPAF-AC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|