Autoria: |
BOTELHO, A. F. M.; OLIVEIRA, M. S. de; SOTO-BLANCO, B.; MELO, M. M. |
Afiliação: |
ANA F. M. BOTELHO, UFMG; MAIRA S. DE OLIVEIRA, UFMG; BENITO SOTO-BLANCO, UFMG; MARÍLIA M. MELO, UFMG. |
Título: |
Computarized electrocardiography in healthy conscious guinea pigs (Cavia porcellus). |
Ano de publicação: |
2016 |
Fonte/Imprenta: |
Pesquisa Veterinária Brasileira, Rio de Janeiro, v. 36, n. 12, p. 1203-1208, dez. 2016. |
Idioma: |
Inglês |
Conteúdo: |
The purpose of this study is to evaluate healthy conscious guinea pigs as a model for electrophysiology assessment and to describe normal electrocardiographic patterns in controlled laboratory environment, establishing the best QT formula for this method. Electrocardiographic recordings of fifty adult conscious guinea pigs were obtained using a computerized electrocardiography. The electrocardiographic measurements of three different tracings were analyzed. The results obtained established normal mean and range values for the parameters: heart rate, waves and intervals of P-QRS-T deflections, as well as the mean cardiac axis. Groups were separated by body weight: group 1 gathered animals with 500-699g and group 2 with animals 700-900g. No differences were found when measurements were compared between groups, showing no significant difference between weight/ body sizes to the electrocardiographic parameters (P<0.05). The mean corrected QT values (QTc) obtained using diverse formulae were significantly different (P<0.05), were the most consistent was Van der Water (QTcV). QTcV values were strongly correlated (r=98) and 95% confidence interval 185.7 to 195.2ms.Considering its simplicity and reliability, the QTcV was deemed the most appropriate to be used for the correction of QT interval in conscious guinea pigs.The results of this study also suggest that the values found can be used as reference for the species |
Palavras-Chave: |
Computerized ECG; ECG computadorizado. |
Thesagro: |
Eletrocardiograma. |
Thesaurus Nal: |
Consciousness; Electrocardiography; Guinea pigs. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/item/155832/1/Computerized-electrocargiography.pdf
|
Marc: |
LEADER 02151naa a2200229 a 4500 001 2064411 005 2017-12-29 008 2016 bl uuuu u00u1 u #d 100 1 $aBOTELHO, A. F. M. 245 $aComputarized electrocardiography in healthy conscious guinea pigs (Cavia porcellus).$h[electronic resource] 260 $c2016 520 $aThe purpose of this study is to evaluate healthy conscious guinea pigs as a model for electrophysiology assessment and to describe normal electrocardiographic patterns in controlled laboratory environment, establishing the best QT formula for this method. Electrocardiographic recordings of fifty adult conscious guinea pigs were obtained using a computerized electrocardiography. The electrocardiographic measurements of three different tracings were analyzed. The results obtained established normal mean and range values for the parameters: heart rate, waves and intervals of P-QRS-T deflections, as well as the mean cardiac axis. Groups were separated by body weight: group 1 gathered animals with 500-699g and group 2 with animals 700-900g. No differences were found when measurements were compared between groups, showing no significant difference between weight/ body sizes to the electrocardiographic parameters (P<0.05). The mean corrected QT values (QTc) obtained using diverse formulae were significantly different (P<0.05), were the most consistent was Van der Water (QTcV). QTcV values were strongly correlated (r=98) and 95% confidence interval 185.7 to 195.2ms.Considering its simplicity and reliability, the QTcV was deemed the most appropriate to be used for the correction of QT interval in conscious guinea pigs.The results of this study also suggest that the values found can be used as reference for the species 650 $aConsciousness 650 $aElectrocardiography 650 $aGuinea pigs 650 $aEletrocardiograma 653 $aComputerized ECG 653 $aECG computadorizado 700 1 $aOLIVEIRA, M. S. de 700 1 $aSOTO-BLANCO, B. 700 1 $aMELO, M. M. 773 $tPesquisa Veterinária Brasileira, Rio de Janeiro$gv. 36, n. 12, p. 1203-1208, dez. 2016.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Unidades Centrais (AI-SEDE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registro Completo
Biblioteca(s): |
Embrapa Amazônia Ocidental. |
Data corrente: |
15/03/2024 |
Data da última atualização: |
21/03/2024 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
PEREIRA, J. C. R.; SANTOS, A. F. dos; ALMEIDA, L. C. C. de. |
Afiliação: |
JOSE CLERIO REZENDE PEREIRA, CPAA; ALVARO FIGUEREDO DOS SANTOS, CPAA; LUIZ CARLOS CORDEIRO DE ALMEIDA. |
Título: |
Mixagem de fungicidas no controle simultâneo do mal-das-folhas e da requeima da seringueira. |
Ano de publicação: |
1984 |
Fonte/Imprenta: |
Fitopatologia Brasileira, v. 9, n. 2, p. 361, jun. 1984. Suplemento. |
Idioma: |
Português |
Notas: |
Edição dos resumos do 17º Congresso da Sociedade Brasileira de Fitopatologia, 1984. Resumo 101. |
Thesagro: |
Seringueira. |
Categoria do assunto: |
-- |
URL: |
https://ainfo.cnptia.embrapa.br/digital/bitstream/doc/1162881/1/F.B-RESUMO-101-PAG-361.pdf
|
Marc: |
LEADER 00571nam a2200145 a 4500 001 2162881 005 2024-03-21 008 1984 bl uuuu u00u1 u #d 100 1 $aPEREIRA, J. C. R. 245 $aMixagem de fungicidas no controle simultâneo do mal-das-folhas e da requeima da seringueira. 260 $aFitopatologia Brasileira, v. 9, n. 2, p. 361, jun. 1984. Suplemento.$c1984 500 $aEdição dos resumos do 17º Congresso da Sociedade Brasileira de Fitopatologia, 1984. Resumo 101. 650 $aSeringueira 700 1 $aSANTOS, A. F. dos 700 1 $aALMEIDA, L. C. C. de
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Amazônia Ocidental (CPAA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|