|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
10/02/2015 |
Data da última atualização: |
15/03/2023 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
AMARAL, C. D. B.; AMAIS, R. S.; FIALHO, L. L.; SCHIAVO, D.; AMORIM, T.; NOGUEIRA, A. R. de A.; ROCHA, F. R. P.; NÓBREGA, J. A. |
Afiliação: |
CLARICE D. B. AMARAL, UNIVERSIDADE FEDERAL DE SAO CARLOS/SÃO CARLOS, SP; RENATA S. AMAIS, CENA-USP/PIRACICABA; LUCIMAR L. FIALHO, UNIVERSIDADE FEDERAL DE SÂO CARLOS/SÃO CARLOS, SP; DANIELA SCHIAVO,, AGILENT TECNOLOGIES BRAZIL; TATIANE AMORIM, Agilent Technologies Brazil; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; FABIO R. P. ROCHA, University of Sao Paulo; JOAQUIM A. NÓBREGA, PROF. UNIVERSIDADE FEDERAL DE SÃO CARLOS, SP. |
Título: |
A novel strategy to determine As, Cr, Hg and V in drinking water by ICP-MS/MS. |
Ano de publicação: |
2015 |
Fonte/Imprenta: |
Analytical Methods, v. 7, p. 1215-1220, 2015. |
DOI: |
DOI: 10.1039/c4ay02811b |
Idioma: |
Inglês |
Conteúdo: |
This work demonstrates the potential of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in trace element analysis. Aiming Hg determination in water, sample preservation requires chloride addition, which presents formation of polyatomic interfering ions as a drawback for the determination of other analytes (e.g. As and V). Thus, the effect of chloride on As, Cr, V and Hg determination and the feasibility of using ICP-MS/MS to circumvent the interference were evaluated. A standard reference material (NIST SRM 1643e) and recoveries from tap water spiked with As, Cr, Hg and V were used for accuracy assessment and for the evaluation of matrix effects. The reaction between Hg and oxygen gas is not favorable in the octopole reaction system (ORS3). Therefore, Hg was accurately determined as a single atom ion (202Hg+) under the same analytical conditions adopted for As, Cr and V determination by monitoring 75As16O+, 52Cr16O+ and 51V16O+ while the ORS3 was pressurized with oxygen gas. The oxygen reaction mode significantly improved the accuracy for As, Cr and V, especially at the lowest spiked level, which is strongly affected by matrix effects. The signal gain in m/z 75 for a solution containing 1 ?g L?1 As in 0.48 mol L ?1 chloride medium was 1974% when employing single quadrupole mode. On the other hand, the signal increased only 7% when 0.75 mL min?1 O2 was used in mass shift mode proving the efficiency of the MS/MS mode. Thus, ICP-MS/MS and ORS3 pressurized with O2 gas effectively reduced the interference, and enhanced the accuracy and sensitivity for some specific isotopes in a complex medium. The limits of detection for V (51V16O+), Cr (52Cr16O+), As (75As16O+) and Hg (202Hg+) were estimated to be 2, 3, 1.6 and 38 ng L?1 at the 99.7% confidence level, respectively. MenosThis work demonstrates the potential of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in trace element analysis. Aiming Hg determination in water, sample preservation requires chloride addition, which presents formation of polyatomic interfering ions as a drawback for the determination of other analytes (e.g. As and V). Thus, the effect of chloride on As, Cr, V and Hg determination and the feasibility of using ICP-MS/MS to circumvent the interference were evaluated. A standard reference material (NIST SRM 1643e) and recoveries from tap water spiked with As, Cr, Hg and V were used for accuracy assessment and for the evaluation of matrix effects. The reaction between Hg and oxygen gas is not favorable in the octopole reaction system (ORS3). Therefore, Hg was accurately determined as a single atom ion (202Hg+) under the same analytical conditions adopted for As, Cr and V determination by monitoring 75As16O+, 52Cr16O+ and 51V16O+ while the ORS3 was pressurized with oxygen gas. The oxygen reaction mode significantly improved the accuracy for As, Cr and V, especially at the lowest spiked level, which is strongly affected by matrix effects. The signal gain in m/z 75 for a solution containing 1 ?g L?1 As in 0.48 mol L ?1 chloride medium was 1974% when employing single quadrupole mode. On the other hand, the signal increased only 7% when 0.75 mL min?1 O2 was used in mass shift mode proving the efficiency of the MS/MS mode. Thus, ICP-MS/MS and ORS3 pressurized with O... Mostrar Tudo |
Palavras-Chave: |
Analitical chemistry; As; Cr; Hg; ICP MS MS; Novel strategy. |
Thesaurus Nal: |
drinking water. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02624naa a2200301 a 4500 001 2008313 005 2023-03-15 008 2015 bl uuuu u00u1 u #d 024 7 $aDOI: 10.1039/c4ay02811b$2DOI 100 1 $aAMARAL, C. D. B. 245 $aA novel strategy to determine As, Cr, Hg and V in drinking water by ICP-MS/MS.$h[electronic resource] 260 $c2015 520 $aThis work demonstrates the potential of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in trace element analysis. Aiming Hg determination in water, sample preservation requires chloride addition, which presents formation of polyatomic interfering ions as a drawback for the determination of other analytes (e.g. As and V). Thus, the effect of chloride on As, Cr, V and Hg determination and the feasibility of using ICP-MS/MS to circumvent the interference were evaluated. A standard reference material (NIST SRM 1643e) and recoveries from tap water spiked with As, Cr, Hg and V were used for accuracy assessment and for the evaluation of matrix effects. The reaction between Hg and oxygen gas is not favorable in the octopole reaction system (ORS3). Therefore, Hg was accurately determined as a single atom ion (202Hg+) under the same analytical conditions adopted for As, Cr and V determination by monitoring 75As16O+, 52Cr16O+ and 51V16O+ while the ORS3 was pressurized with oxygen gas. The oxygen reaction mode significantly improved the accuracy for As, Cr and V, especially at the lowest spiked level, which is strongly affected by matrix effects. The signal gain in m/z 75 for a solution containing 1 ?g L?1 As in 0.48 mol L ?1 chloride medium was 1974% when employing single quadrupole mode. On the other hand, the signal increased only 7% when 0.75 mL min?1 O2 was used in mass shift mode proving the efficiency of the MS/MS mode. Thus, ICP-MS/MS and ORS3 pressurized with O2 gas effectively reduced the interference, and enhanced the accuracy and sensitivity for some specific isotopes in a complex medium. The limits of detection for V (51V16O+), Cr (52Cr16O+), As (75As16O+) and Hg (202Hg+) were estimated to be 2, 3, 1.6 and 38 ng L?1 at the 99.7% confidence level, respectively. 650 $adrinking water 653 $aAnalitical chemistry 653 $aAs 653 $aCr 653 $aHg 653 $aICP MS MS 653 $aNovel strategy 700 1 $aAMAIS, R. S. 700 1 $aFIALHO, L. L. 700 1 $aSCHIAVO, D. 700 1 $aAMORIM, T. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aROCHA, F. R. P. 700 1 $aNÓBREGA, J. A. 773 $tAnalytical Methods$gv. 7, p. 1215-1220, 2015.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 168 | |
161. | | GONZALEZ, M. H.; SOUZA, G. B. D.; OLIVEIRA, R. V. DE; FORATO, L. A.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Microwave-assisted digestion procedures for biological samples with diluted nitric acid: identification of reaction products. Talanta, v. 79, n. 2, p. 396-401, jul. 2009.Tipo: Artigo em Periódico Indexado | Circulação/Nível: A - 1 |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
162. | | MENEZES, E. A.; CHAVES, F. S.; GONZALEZ, M. H.; MATOS, W. O.; SOUZA, G. B. de; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Microwave radiation strategies analytical chemistry: an alternative for minimization of chemical wastes and analytical throughput. In: INTERNATIONAL SYMPOSIUM ON RESIDUE MANAGEMENT IN UNIVERSITIES, 3.; ENCONTRO NACIONAL DE SEGURANÇA EM QUÍMICA, 4., 2006, São Carlos: USP, 2006. 3 f. 1 CD-ROMTipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
163. | | MORAES, D. P. de; BIZZI, C. A.; NÓBREGA, J. A.; FLORES, E. M. de M.; NOGUEIRA, A. R. de A.; BARIN, J. S.; MESKO, M. F. Preparo de amostras assistido por radiação micro-ondas. In: KRUG, F. J.; ROCHA, F. R. P. Métodos de preparo de amostras para análise elementar. 2 ed. São Paulo: EditSBQ, 2019. p.299-369.Tipo: Capítulo em Livro Técnico-Científico |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
165. | | ROSA, C. R.; DAKUZAKU, C. S.; FRESCHI, G. P. G.; GOMES NETO, J. A.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Método para a determinação de Se em suspensão de vegetais empregado GFAAS. In: ENCONTRO REGIONAL DE QUÍMICA DA SOCIEDADE BRASILEIRA DE QUÍMICA, 13.; SEMANA DA QUÍMICA, 31., 2001, Jaboticabal, SP. Anais... Jaboticabal: Instituto de Química-UNESP, 2001. p.125, QA-63.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
166. | | MARIONI, B.; BARAO-NÓBREGA, J. A. L.; BOTERO-ARIAS, R.; MUNIZ, F.; CAMPOS, Z.; SILVEIRA, R. da; MAGNUSSON, W. E.; VILLAMARÍN, F. Science and conservation of Amazonian crocodilians: a historical review. Aquatic conservation: marine and freshwater ecosystems, v. 31, p. 1056-1067, 2021.Tipo: Artigo em Periódico Indexado | Circulação/Nível: A - 2 |
Biblioteca(s): Embrapa Pantanal. |
| |
167. | | CARRILHO, E. N. V. M.; NOGUEIRA, A. R. de A.; NOBREGA, J. A.; SOUZA, G. B. de; CRUZ, G. M. D. Teores de gordura e proteína em materiais biológicos e carbono residual após decomposição assistida por microondas. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 11., 2001, Campinas, SP. Desafios da química analítica no século XXI. Anais.... Campinas: ENQA, 2001. TA-2.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
168. | | ROSA, C. R.; FRESCHI, G. G.; MORAES, M. de; GOMES NETO, J. A.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A.; SACRAMENTO, L. V. Tungsten permanent chemical modifier for fast estimationsof contents in soil by graphite furnace atomic absorption spectrometry. Journal of agricultural and Food Chemistry, v. 51, p. 3920-3923, 2003.Tipo: Artigo em Periódico Indexado | Circulação/Nível: Internacional - A |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 168 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|