|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo |
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
07/07/2021 |
Data da última atualização: |
28/09/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
MOREIRA, L. S; COSTA, F. S; MACHADO, R. C.; NOGUEIRA, A. R. de A.; GONZALEZ, M. H.; SILVA, E. G. P. da; AMARAL, C. D. B. do. |
Afiliação: |
LUANA SANTOS MOREIRA, UFPR; FLORIATAN SANTOS COSTA, UFPR; RAQUEL CARDOSO MACHADO, UFSCAR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE; MARIO HENRIQUE GONZALEZ, UNESP; ERIK GALVÃO PARANHOS DA SILVA, UESC; CLARICE DIAS BRITTO DO AMARAL, UFPR. |
Título: |
Self-organizing map applied to the choice of internal standards for the determination of Cd, Pb, Sn, and platinum group elements by inductively coupled plasma mass spectrometry. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Talanta, v. 233, oct. 2021, 122534. |
Páginas: |
6 p. |
ISSN: |
0039-9140 |
DOI: |
https://doi.org/10.1016/j.talanta.2021.122534 |
Idioma: |
Inglês |
Conteúdo: |
The behaviors of internal standards, according to different flow rates of the cell collision gas (He), were studied for the determination of Cd, Pb, Pd, Pt, Rh, and Sn in samples of fish and mollusks by inductively coupled plasma mass spectrometry (ICP-MS). The elements Bi, Ge, In, Sc, and Y were selected as internal standards, considering their masses and first ionization energies. Addition and recovery experiments were carried out at three concentration levels to evaluate the accuracy of the method applied for the analysis of two samples with different matrices. The results were evaluated using a self-organizing map (SOM). The best analyte/IS pairs were as follows: 114Cd+/74Ge+, 195Pt+/74Ge+, and 208Pb+/74Ge+. For 103Rh+, 106Pd+, and 120Sn+, greater accuracy was achieved without use of an internal standard. Helium gas (2.8 mL min -1) was used in the collision cell for the analytes, except for Sn, and recoveries ranged from 98 to 101% under optimal conditions. The use of SOM as an exploratory analysis tool was an effective approach for selection of the most appropriate internal standards. |
Palavras-Chave: |
Bivalve mollusks; ICP-MS; PGEs; Self-organizing map; Toxic elements. |
Thesaurus Nal: |
Fish. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02044naa a2200301 a 4500 001 2132829 005 2021-09-28 008 2021 bl uuuu u00u1 u #d 022 $a0039-9140 024 7 $ahttps://doi.org/10.1016/j.talanta.2021.122534$2DOI 100 1 $aMOREIRA, L. S 245 $aSelf-organizing map applied to the choice of internal standards for the determination of Cd, Pb, Sn, and platinum group elements by inductively coupled plasma mass spectrometry.$h[electronic resource] 260 $c2021 300 $a6 p. 520 $aThe behaviors of internal standards, according to different flow rates of the cell collision gas (He), were studied for the determination of Cd, Pb, Pd, Pt, Rh, and Sn in samples of fish and mollusks by inductively coupled plasma mass spectrometry (ICP-MS). The elements Bi, Ge, In, Sc, and Y were selected as internal standards, considering their masses and first ionization energies. Addition and recovery experiments were carried out at three concentration levels to evaluate the accuracy of the method applied for the analysis of two samples with different matrices. The results were evaluated using a self-organizing map (SOM). The best analyte/IS pairs were as follows: 114Cd+/74Ge+, 195Pt+/74Ge+, and 208Pb+/74Ge+. For 103Rh+, 106Pd+, and 120Sn+, greater accuracy was achieved without use of an internal standard. Helium gas (2.8 mL min -1) was used in the collision cell for the analytes, except for Sn, and recoveries ranged from 98 to 101% under optimal conditions. The use of SOM as an exploratory analysis tool was an effective approach for selection of the most appropriate internal standards. 650 $aFish 653 $aBivalve mollusks 653 $aICP-MS 653 $aPGEs 653 $aSelf-organizing map 653 $aToxic elements 700 1 $aCOSTA, F. S 700 1 $aMACHADO, R. C. 700 1 $aNOGUEIRA, A. R. de A. 700 1 $aGONZALEZ, M. H. 700 1 $aSILVA, E. G. P. da 700 1 $aAMARAL, C. D. B. do 773 $tTalanta$gv. 233, oct. 2021, 122534.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 51 | |
2. | | FREITAS, E. R.; SAKOMURA, N. K.; MARTINS GONZALEZ, M.; BARBOSA, N. A. A. Comparação de métodos de determinação da gravidade específica de ovos de poedeiras comerciais . Pesquisa Agropecuária Brasileira, Brasília, DF, v. 39, n. 5, p. 509-512, maio 2004 Notas Científicas.
Título em inglês: Comparison of methods to measure the specific gravity of laying hen eggs.Biblioteca(s): Embrapa Unidades Centrais. |
| |
9. | | GONZALEZ, M. H.; SOUZA, G. B. de; NOGUEIRA, A. R. de A. Efeitos térmicos causados pelos métodos de secagem em amostras de guandú. In: CONGRESSO BRASILEIRO DE QUÍMICA 42.; JORNADA BRASILEIRA DE INICIAÇÃO CIENTÍFICA EM QUÍMICA, 15.; MARATONA DE QUÍMICA 10.; FEIRA DE PROJETOS DE QUÍMICA-FEPROQUIM, 3.; ENCONTRO DE QUÍMICA PROFISSIONAL - EMQUIMPRO, 5.; EXPOQUÍMICA, 2002, Rio de Janeiro. Química, energia e desenvolvimento: Livro de resumo. Rio de Janeiro: ABQ, 2002. p.532.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
13. | | ARAÚJO, G. C. L.; GONZALEZ, M. H.; NOGUEIRA, A. R. de A.; NÓBREGA, J. A. Effect of nitric acid concentration on closed-vessel microwave-assisted digestation of plant materials. In: RIO SYMPOSIUM ON ATOMIC SPECTROMETRY, 17., 2002, Florianópolis, SC. Abstracts... Florianópolis: UFSC, 2002. p.137. ICP Information Newsletter, v.28, n.1, jun 2002.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
19. | | GONZALEZ, M. H.; OLIVEIRA, R. V.; FORATO, L. A.; NÓBREGA, J. A.; NOGUEIRA, A. R. de A. Caracterização dos produtos reacionais resultantes da digestão ácida de materiais biológicos assistida por radiação microondas. In: ENCONTRO NACIONAL DE QUÍMICA ANALÍTICA, 14., 2007, João Pessoa, PB. Anais... João Pessoa: SBQA, 2007. 1 CD-ROM.Tipo: Resumo em Anais de Congresso |
Biblioteca(s): Embrapa Instrumentação; Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 51 | |
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|