|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Solos. Para informações adicionais entre em contato com cnps.biblioteca@embrapa.br. |
Registro Completo |
Biblioteca(s): |
Embrapa Solos. |
Data corrente: |
29/09/2014 |
Data da última atualização: |
08/11/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Autoria: |
SANTOS, V. B. dos; FAVA, E. L.; PESSOA-NETO, O. D.; BIANCHI, S. R.; FARIA, R. C.; FATIBELLO-FILHO, O. |
Afiliação: |
Vagner Bezerra dos Santos, Universidade Federal de São Carlos; Elson Luiz Fava, Universidade Federal de São Carlos; Osmundo Dantas Pessoa-Neto, Universidade Federal de São Carlos; SILMARA ROSSANA BIANCHI, CNPS; Ronaldo Censi Faria, Universidade Federal de São Carlos; Orlando Fatibello-Filho, Universidade Federal de São Carlos. |
Título: |
A versatile and robust electrochemical flow cell with a boron-doped diamond electrode for simultaneous determination of Zn2+ and Pb2+ ions in water samples. |
Ano de publicação: |
2014 |
Fonte/Imprenta: |
Analytical Methods, v. 6, p. 8526-8534, 2014. |
DOI: |
https://doi.org/10.1039/C4AY01811G |
Idioma: |
Inglês |
Conteúdo: |
A versatile and robust thermostatted electrochemical flow cell (EFC) with a boron-doped diamond electrode (BDD) detector was employed to perform two distinct flow-injection electrochemical approaches. In the first approach, differential pulse anodic stripping voltammetry (DPASV) using a flowbatch analysis (FBA) is proposed. In the second approach, multiple pulse amperometry (MPA) employing multicommutation flow analysis (MCFA) is also presented. Both approaches were employed to simultaneously determine Zn2+ and Pb2+ in water samples. For this, a screen-printed electrode (SPE) was developed, and a BDD electrode was coupled to it and was inserted into the EFC. By employing the FBA with the DPASV technique, two analytical curves in concentration ranges from 11.5 to 80.6 mg L1 and 0.64 to 10.9 mg L1 for simultaneous determination of Zn2+ and Pb2+, respectively, were obtained. Moreover, limits of detection (LDs) of 0.62 mg L1 and 0.19 mg L1 were estimated respectively and a sampling frequency of 12 h1 was obtained. For MCFA with MPA, analytical curves from 830 to 4980 mg L1 and 140 to 820 mg L1 for simultaneous determination of Zn2+ and Pb2+ with LDs of 220.0 mg L1 and 41.0 mg L1 and a sampling frequency of 67 h1 were obtained. The developed EFC allowed a full on-line automation of the methods, covering the pretreatment of BDD, addition of standard solutions, dilutions, thermostatted control, and detection with and without electrochemical preconcentration. In addition, the low waste generation of only 700 mL may be useful for green chemistry purposes and sustainable research. MenosA versatile and robust thermostatted electrochemical flow cell (EFC) with a boron-doped diamond electrode (BDD) detector was employed to perform two distinct flow-injection electrochemical approaches. In the first approach, differential pulse anodic stripping voltammetry (DPASV) using a flowbatch analysis (FBA) is proposed. In the second approach, multiple pulse amperometry (MPA) employing multicommutation flow analysis (MCFA) is also presented. Both approaches were employed to simultaneously determine Zn2+ and Pb2+ in water samples. For this, a screen-printed electrode (SPE) was developed, and a BDD electrode was coupled to it and was inserted into the EFC. By employing the FBA with the DPASV technique, two analytical curves in concentration ranges from 11.5 to 80.6 mg L1 and 0.64 to 10.9 mg L1 for simultaneous determination of Zn2+ and Pb2+, respectively, were obtained. Moreover, limits of detection (LDs) of 0.62 mg L1 and 0.19 mg L1 were estimated respectively and a sampling frequency of 12 h1 was obtained. For MCFA with MPA, analytical curves from 830 to 4980 mg L1 and 140 to 820 mg L1 for simultaneous determination of Zn2+ and Pb2+ with LDs of 220.0 mg L1 and 41.0 mg L1 and a sampling frequency of 67 h1 were obtained. The developed EFC allowed a full on-line automation of the methods, covering the pretreatment of BDD, addition of standard solutions, dilutions, thermostatted control, and detection with and without electrochemical preconcentration. In addition, the low wa... Mostrar Tudo |
Palavras-Chave: |
Diamond eletrode; Eletrodo de diamante; Pb2+; Zn2+. |
Thesagro: |
Boro. |
Thesaurus Nal: |
boron. |
Categoria do assunto: |
P Recursos Naturais, Ciências Ambientais e da Terra |
Marc: |
LEADER 02419naa a2200265 a 4500 001 1996038 005 2021-11-08 008 2014 bl uuuu u00u1 u #d 024 7 $ahttps://doi.org/10.1039/C4AY01811G$2DOI 100 1 $aSANTOS, V. B. dos 245 $aA versatile and robust electrochemical flow cell with a boron-doped diamond electrode for simultaneous determination of Zn2+ and Pb2+ ions in water samples.$h[electronic resource] 260 $c2014 520 $aA versatile and robust thermostatted electrochemical flow cell (EFC) with a boron-doped diamond electrode (BDD) detector was employed to perform two distinct flow-injection electrochemical approaches. In the first approach, differential pulse anodic stripping voltammetry (DPASV) using a flowbatch analysis (FBA) is proposed. In the second approach, multiple pulse amperometry (MPA) employing multicommutation flow analysis (MCFA) is also presented. Both approaches were employed to simultaneously determine Zn2+ and Pb2+ in water samples. For this, a screen-printed electrode (SPE) was developed, and a BDD electrode was coupled to it and was inserted into the EFC. By employing the FBA with the DPASV technique, two analytical curves in concentration ranges from 11.5 to 80.6 mg L1 and 0.64 to 10.9 mg L1 for simultaneous determination of Zn2+ and Pb2+, respectively, were obtained. Moreover, limits of detection (LDs) of 0.62 mg L1 and 0.19 mg L1 were estimated respectively and a sampling frequency of 12 h1 was obtained. For MCFA with MPA, analytical curves from 830 to 4980 mg L1 and 140 to 820 mg L1 for simultaneous determination of Zn2+ and Pb2+ with LDs of 220.0 mg L1 and 41.0 mg L1 and a sampling frequency of 67 h1 were obtained. The developed EFC allowed a full on-line automation of the methods, covering the pretreatment of BDD, addition of standard solutions, dilutions, thermostatted control, and detection with and without electrochemical preconcentration. In addition, the low waste generation of only 700 mL may be useful for green chemistry purposes and sustainable research. 650 $aboron 650 $aBoro 653 $aDiamond eletrode 653 $aEletrodo de diamante 653 $aPb2+ 653 $aZn2+ 700 1 $aFAVA, E. L. 700 1 $aPESSOA-NETO, O. D. 700 1 $aBIANCHI, S. R. 700 1 $aFARIA, R. C. 700 1 $aFATIBELLO-FILHO, O. 773 $tAnalytical Methods$gv. 6, p. 8526-8534, 2014.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Solos (CNPS) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Agricultura Digital. Para informações adicionais entre em contato com cnptia.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Agricultura Digital. |
Data corrente: |
09/03/2012 |
Data da última atualização: |
09/03/2012 |
Tipo da produção científica: |
Software |
Autoria: |
OLIVEIRA, L. H. M. de; MAGALHÃES, R. B. |
Afiliação: |
LEANDRO HENRIQUE MENDONÇA DE OLIVEIRA, CNPTIA; RODRIGO BUSTAMANTE MAGALHÃES, Estagiário do CNPTIA, IC/Unicamp. |
Título: |
NewsCap - News Capture. Versão 2.0. |
Ano de publicação: |
2011 |
Fonte/Imprenta: |
Campinas: Embrapa Informática Agropecuária, 2011. |
Descrição Física: |
1 CD-ROM. |
Idioma: |
Português |
Conteúdo: |
Este software captura clippings de notícias, ou seja recortes de notícias de interesse, de um site determinado, fornecida sua URI, e sob um formato pré-definido por meio de um robô de busca. A partir desses recortes de notícias, o software cria uma base de dados textual, na qual cada texto corresponde a uma única notícia, identificada pela sua fonte, data e horário de publicação, e com marcadores XML. Os marcadores separam título, autoria, fonte de publicação, data de publicação e corpo da notícia. O software pode ser utilizado de forma independente ou como um módulo incorporado a qualquer outro software que necessite capturar partes específicas de um determinado site, desde que configurado para tal. Ele foi configurado, inicialmente, para capturar notícias sobre a cultura de cana-de-açúcar do site Jornal da Cana, exemplo que acompanha esta distribuição. Além de corrigir alguns erros a versão 2 deste software obteve as seguintes melhorias: 1) a coleta das notícias mantendo a acentuação das palavras para o Portugues do Brasil, 2) atualização total da base de noticias coletadas durante o ano de 2010/2011 com palavras acentuadas e 3) melhora no desempenho. |
Palavras-Chave: |
Base de dados textual; Recortes de notícias; Software. |
Thesaurus NAL: |
Databases. |
Categoria do assunto: |
X Pesquisa, Tecnologia e Engenharia |
Marc: |
LEADER 01692nam a2200181 a 4500 001 1918160 005 2012-03-09 008 2011 bl uuuu u0uu1 u #d 100 1 $aOLIVEIRA, L. H. M. de 245 $aNewsCap - News Capture. Versão 2.0. 260 $aCampinas: Embrapa Informática Agropecuária$c2011 300 $c1 CD-ROM. 520 $aEste software captura clippings de notícias, ou seja recortes de notícias de interesse, de um site determinado, fornecida sua URI, e sob um formato pré-definido por meio de um robô de busca. A partir desses recortes de notícias, o software cria uma base de dados textual, na qual cada texto corresponde a uma única notícia, identificada pela sua fonte, data e horário de publicação, e com marcadores XML. Os marcadores separam título, autoria, fonte de publicação, data de publicação e corpo da notícia. O software pode ser utilizado de forma independente ou como um módulo incorporado a qualquer outro software que necessite capturar partes específicas de um determinado site, desde que configurado para tal. Ele foi configurado, inicialmente, para capturar notícias sobre a cultura de cana-de-açúcar do site Jornal da Cana, exemplo que acompanha esta distribuição. Além de corrigir alguns erros a versão 2 deste software obteve as seguintes melhorias: 1) a coleta das notícias mantendo a acentuação das palavras para o Portugues do Brasil, 2) atualização total da base de noticias coletadas durante o ano de 2010/2011 com palavras acentuadas e 3) melhora no desempenho. 650 $aDatabases 653 $aBase de dados textual 653 $aRecortes de notícias 653 $aSoftware 700 1 $aMAGALHÃES, R. B.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Agricultura Digital (CNPTIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Expressão de busca inválida. Verifique!!! |
|
|